Determination of Resonance Raman Cross-Sections for Use in Biological SERS Sensing with Femtosecond Stimulated Raman Spectroscopy
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Surface-enhanced Raman spectroscopy (SERS) is a promising technique for in vivo bioanalyte detection, but accurate characterization of SERS biosensors can be challenging due to difficulties in differentiating resonance and surface enhancement contributions to the Raman signal. Here, we quantitate the resonance Raman cross-sections for a commonly used near-infrared SERS dye, 3,3'-diethylthiatricarbocyanine (DTTC). It is typically challenging to measure resonance Raman cross-sections for fluorescent dye molecules due to the overwhelming isoenergetic fluorescence signal. To overcome this issue, we used etalon-based femtosecond stimulated Raman spectroscopy, which is intrinsically designed to acquire a stimulated Raman signal without strong fluorescence or interference from signals resulting from other four-wave mixing pathways. Using this technique, we found that the cross-sections for most of the resonantly enhanced modes in DTTC exceed 10(-25) cm(2)/molecule. These cross-sections lead to high signal magnitude SERS signals from even weakly enhancing SERS substrates, as much of what appears to be a SERS signal is actually coming from the intrinsically strong resonance Raman signal. Our work will lead to a more accurate determination of SERS enhancement factors and SERS substrate characterization in the biologically relevant near-infrared region, ultimately leading to a more widespread use of SERS for biosensing and bioimaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Cai, H., Zhu, J., Chen, G., Liu, L., He, G. S., & Zhang, X. (2011) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2929 · Cited by 19
Cited by
Super-multiplex vibrational imaging
Wei, L., Chen, Z., Shi, L., Long, R., Anzalone, A. V., Zhang, L., Hu, F., Yuste, R., Cornish, V. W., & Min, W. (2017) · Nature · doi:10.1038/nature22051 · Cited by 514
Stimulated Raman Scattering: From Bulk to Nano
Prince, R. C., Frontiera, R. R., & Potma, E. O. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00545 · Cited by 350
Self-citationYu, J. H., Steinberg, I., Davis, R. M., Malkovskiy, A. V., Zlitni, A., Radzyminski, R. K., Jung, K. O., Chung, D. T., Curet, L. D., D’Souza, A. L., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c07470 · Cited by 67
Eremina, O. E., Eremin, D. B., Czaja, A., & Zavaleta, C. (2021) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.1c01504 · Cited by 18
Metadata
- Authors
- Silva, W. R., Keller, E. L., & Frontiera, R. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-07-09
- Volume
- 86
- Issue
- 15
- Pages
- 7782-7787
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2322837597
- Cited by
- 47
- References
- 3
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.