The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Smartphone-Based Simultaneous pH and Nitrite Colorimetric Determination for Paper Microfluidic Devices
Open accessAbstract
In this work, an Android application for measurement of nitrite concentration and pH determination in combination with a low-cost paper-based microfluidic device is presented. The application uses seven sensing areas, containing the corresponding immobilized reagents, to produce selective color changes when a sample solution is placed in the sampling area. Under controlled conditions of light, using the flash of the smartphone as a light source, the image captured with the built-in camera is processed using a customized algorithm for multidetection of the colored sensing areas. The developed image-processing allows reducing the influence of the light source and the positioning of the microfluidic device in the picture. Then, the H (hue) and S (saturation) coordinates of the HSV color space are extracted and related to pH and nitrite concentration, respectively. A complete characterization of the sensing elements has been carried out as well as a full description of the image analysis for detection. The results show good use of a mobile phone as an analytical instrument. For the pH, the resolution obtained is 0.04 units of pH, 0.09 of accuracy, and a mean squared error of 0.167. With regard to nitrite, 0.51% at 4.0 mg L(-1) of resolution and 0.52 mg L(-1) as the limit of detection was achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital Image Processing Using MATLAB
González, R. C., Woods, R. E., & Eddins, S. L. (2003) · Cited by 7,079
Digital Image Processing: PIKS Inside
Pratt, W. K. (2002) · Wiley eBooks · doi:10.1002/0471221325 · Cited by 4,340
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
McDonagh, C., Burke, C. S., & MacCraith, B. D. (2008) · Chemical Reviews · doi:10.1021/cr068102g · Cited by 1,026
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Point-of-care colorimetric detection with a smartphone
Shen, L., Hagen, J. A., & Papautsky, I. (2012) · Lab on a Chip · doi:10.1039/c2lc40741h · Cited by 609
Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors
Delaney, J. L., Hogan, C. F., Tian, J., & Shen, W. (2011) · Analytical Chemistry · doi:10.1021/ac102392t · Cited by 592
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Smartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva
Oncescu, V., O'Dell, D., & Erickson, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50431j · Cited by 362
A Colorimetric Sensor Array for Organics in Water
Zhang, C., & Suslick, K. S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052606z · Cited by 303
Wang, S., Zhao, X., Khimji, I., Akbas, R., Qiu, W., Edwards, D., Cramer, D. W., Ye, B., & Demirci, U. (2011) · Lab on a Chip · doi:10.1039/c1lc20479c · Cited by 254
Simultaneous Photographing of Oxygen and pH In Vivo Using Sensor Films
Meier, R. J., Schreml, S., Wang, X., Landthaler, M., Babilas, P., & Wolfbeis, O. S. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201104530 · Cited by 135
A simple and smart telemedicine device for developing regions: a pocket-sized colorimetric reader
Lee, D.-S., Jeon, B. G., Ihm, C., Park, J., & Jung, M. Y. (2010) · Lab on a Chip · doi:10.1039/c0lc00209g · Cited by 112
Microfluidic oxygen imaging using integrated optical sensor layers and a color camera
Ungerböck, B., Charwat, V., Ertl, P., & Mayr, T. (2013) · Lab on a Chip · doi:10.1039/c3lc41315b · Cited by 96
Colorimetric analysis of water and sand samples performed on a mobile phone
Iqbal, Z., & Bjorklund, R. B. (2011) · Talanta · doi:10.1016/j.talanta.2011.03.016 · Cited by 36
Salmerón, J. F., Gómez‐Robledo, L., Carvajal, M. A., Huertas, R., Moyano, M. J., Gordillo, B., Palma, A. J., Heredia, F. J., & Melgosa, M. (2012) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2012.02.025 · Cited by 24
Self-citation
Cited by
Beyond the lateral flow assay: A review of paper-based microfluidics
Carrell, C., Kava, A., Nguyen, M., Menger, R., Munshi, Z., Call, Z., Nussbaum, M., & Henry, C. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2018.12.002 · Cited by 336
Small Molecule Optical Probes for Detection of H2S in Water Samples: A Review
M, R., Kulkarni, R. M., & Sunil, D. (2024) · ACS Omega · doi:10.1021/acsomega.3c08573 · Cited by 38
Metadata
- Authors
- Lopez-Ruiz, N., Curto, V. F., Erenas, M. M., Benito-Lopez, F., Diamond, D., Palma, A. J., & Capitan-Vallvey, L. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-09-09
- Volume
- 86
- Issue
- 19
- Pages
- 9554-9562
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2319874642
- Cited by
- 423
- References
- 19
- FWCI
- 15.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.