The DOI matches its Crossref record.
Point-of-care colorimetric detection with a smartphone
Abstract
Paper-based immunoassays are becoming powerful and low-cost diagnostic tools, especially in resource-limited settings. Inexpensive methods for quantifying these assays have been shown using desktop scanners, which lack portability, and cameras, which suffer from the ever changing ambient light conditions. In this work, we introduce a novel approach of quantifying colors of colorimetric diagnostic assays with a smartphone that allows high accuracy measurements in a wide range of ambient conditions, making it a truly portable system. Instead of directly using the red, green, and blue (RGB) intensities of the color images taken by a smartphone camera, we use chromaticity values to construct calibration curves of analyte concentrations. We demonstrate the high accuracy of this approach in pH measurements with linear response ranges of 1-12. These results are comparable to those reported using a desktop scanner or silicon photodetectors. To make the approach adoptable under different lighting conditions, we developed a calibration technique to compensate for measurement errors due to variability in ambient light. This technique is applicable to a number of common light sources, such as sun light, fluorescent light, or smartphone LED light. Ultimately, the entire approach can be integrated in an "app" to enable one-click reading, making our smartphone based approach operable without any professional training or complex instrumentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
Lopez-Ruiz, N., Curto, V. F., Erenas, M. M., Benito-Lopez, F., Diamond, D., Palma, A. J., & Capitan-Vallvey, L. F. (2014) · Analytical Chemistry · doi:10.1021/ac5019205 · Cited by 423
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
Metadata
- Authors
- Shen, L., Hagen, J. A., & Papautsky, I.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 21
- Pages
- 4240
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2120243796
- Cited by
- 609
- References
- 0
- FWCI
- 17.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point-of-care colorimetric detection with a smartphone. https://app.cochat.ai/papers/10.1039/c2lc40741h
- The paper
- Shen, L., Hagen, J. A., & Papautsky, I. (2012). Point-of-care colorimetric detection with a smartphone. Lab on a Chip. https://doi.org/10.1039/c2lc40741h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.