High-Throughput Thermal Stability Analysis of a Monoclonal Antibody by Attenuated Total Reflection FT-IR Spectroscopic Imaging
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The use of biotherapeutics, such as monoclonal antibodies, has markedly increased in recent years. It is thus essential that biotherapeutic production pipelines are as efficient as possible. For the production process, one of the major concerns is the propensity of a biotherapeutic antibody to aggregate. In addition to reducing bioactive material recovery, protein aggregation can have major effects on drug potency and cause highly undesirable immunological effects. It is thus essential to identify processing conditions which maximize recovery while avoiding aggregation. Heat resistance is a proxy for long-term aggregation propensity. Thermal stability assays are routinely performed using various spectroscopic and scattering detection methods. Here, we evaluated the potential of macro attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectroscopic imaging as a novel method for the high-throughput thermal stability assay of a monoclonal antibody. This chemically specific visualization method has the distinct advantage of being able to discriminate between monomeric and aggregated protein. Attenuated total reflection is particularly suitable for selectively probing the bottom of vessels, where precipitated aggregates accumulate. With focal plane array detection, we tested 12 different buffer conditions simultaneously to assess the effect of pH and ionic strength on protein thermal stability. Applying the Finke model to our imaging kinetics allowed us to determine the rate constants of nucleation and autocatalytic growth. This analysis demonstrated the greater stability of our immunoglobulin at higher pH and moderate ionic strength, revealing the key role of electrostatic interactions. The high-throughput approach presented here has significant potential for analyzing the stability of biotherapeutics as well as any other biological molecules prone to aggregation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infrared spectroscopy of proteins
Barth, A. (2007) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2007.06.004 · Cited by 5,129
Delivery of Therapeutic Proteins
Pisal, D. S., Kosloski, M. P., & Balu-Iyer, S. V. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22054 · Cited by 532
Distinct β-sheet structure in protein aggregates determined by ATR-FTIR spectroscopy
Shivu, B., Seshadri, S., Li, J., Oberg, K. A., Uversky, V. N., & Fink, A. L. (2013) · Biochemistry · doi:10.1021/bi400625v · Cited by 289
Boulet-Audet, M., Buffeteau, T., Boudreault, S., Daugey, N., & Pézolet, M. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp101763y · Cited by 62
Self-citation
Cited by
Current PAT Landscape in the Downstream Processing of Biopharmaceuticals
Sathiyapriyan, P., Mukherjee, S., Vogel, T., Essen, L., Boerema, D., Vey, M., & Kalina, U. (2025) · Analytical Science Advances · doi:10.1002/ansa.70013 · Cited by 45
In‐Line Monitoring of Protein Concentration With MIR Spectroscopy During UFDF
Milewska, A., Baekelandt, G., Boutaieb, S., Mozin, V., & Falconbridge, A. (2023) · Engineering in Life Sciences · doi:10.1002/elsc.202200050 · Cited by 18
“ATR-FTIR is a method where the effective pathlength is significantly reduced due to the high refractive index infrared-transparent internal reflection element (IRE) [23, 24].”
MethodBueno, J., Long, D., Kauffman, J. F., & Arzhantsev, S. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01606 · Cited by 14
Qiu, C., & Arzhantsev, S. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2018.06.003 · Cited by 11
Metadata
- Authors
- Boulet-Audet, M., Byrne, B., & Kazarian, S. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-09-26
- Volume
- 86
- Issue
- 19
- Pages
- 9786-9793
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2062100461
- Cited by
- 59
- References
- 4
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Throughput Thermal Stability Analysis of a Monoclonal Antibody by Attenuated Total Reflection FT-IR Spectroscopic Imaging. https://app.cochat.ai/papers/10.1021/ac502529q
- The paper
- Boulet-Audet, M., Byrne, B., & Kazarian, S. G. (2014). High-Throughput Thermal Stability Analysis of a Monoclonal Antibody by Attenuated Total Reflection FT-IR Spectroscopic Imaging. Analytical Chemistry. https://doi.org/10.1021/ac502529q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.