CoChat

Real-time Ratiometric Fluorescent Assay for Alkaline Phosphatase Activity with Stimulus Responsive Infinite Coordination Polymer Nanoparticles

Deng, Jingjing, Yu, Ping, Wang, Yuexiang, Mao, Lanqun · 2015 · Analytical Chemistry
Cited by 237

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

This study demonstrates a novel ratiometric fluorescent method for real-time alkaline phosphatase (ALP) activity assay with stimulus responsive infinite coordination polymer (ICP) nanoparticles as the probe. The ICP nanoparticles used in this study are composed of two components; one is the supramolecular ICP network formed with guanine monophosphate (GMP) as the ligand and Tb(3+) as the central metal ion, and the other is a fluorescent dye, i.e., 7-amino-4-methyl coumarin (coumarin) encapsulated into the ICP network. Upon being excited at 315 nm, the ICP network itself emits green fluorescence at 552 nm. Coumarin dye encapsulated in the ICP network emits weak fluorescence at 450 nm upon excitation at the same wavelength (315 nm), and this fluorescence emission becomes strong when the encapsulated dye is released from the network into the solution phase. Hence, we develop a ratiometric fluorescent assay based on the ALP-induced destruction of the supramolecular ICP network and the release of coumarin. This mechanism can be used for real-time ratiometric fluorescent monitoring of ALP activity by continuously measuring the ratio of fluorescent intensity at the wavelength of 552 nm (F552) to that at 450 nm (F450) (F552/F450) in the time-dependent fluorescent spectra of the coumarin@Tb-GMP suspension containing ALP with different activities. Under the experimental conditions employed here, the F552/F450 value is linear with the ALP activity within a range from 0.025 U/mL to 0.2 U/mL. The detection limit is down to 0.010 U/mL (S/N = 3). Moreover, the assay developed here is employed for ALP inhibitor evaluation. This study offers a simple yet sensitive method for real-time ALP activity assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac504773n

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 237

Metadata

Authors
Deng, J., Yu, P., Wang, Y., & Mao, L.
Venue
Analytical Chemistry
Published
2015-02-10
Volume
87
Issue
5
Pages
3080-3086
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2332536232
Cited by
237
References
30
FWCI
13.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time Ratiometric Fluorescent Assay for Alkaline Phosphatase Activity with Stimulus Responsive Infinite Coordination Polymer Nanoparticles. https://app.cochat.ai/papers/10.1021/ac504773n
The paper
Deng, J., Yu, P., Wang, Y., & Mao, L. (2015). Real-time Ratiometric Fluorescent Assay for Alkaline Phosphatase Activity with Stimulus Responsive Infinite Coordination Polymer Nanoparticles. Analytical Chemistry. https://doi.org/10.1021/ac504773n

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.