The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrogenerated Chemiluminescence DNA Biosensor Based on Hairpin DNA Probe Labeled with Ruthenium Complex
Abstract
A highly selective electrogenerated chemiluminescence (ECL) biosensor for the detection of target single-strand DNA (ss-DNA) was developed using hairpin DNA as the recognition element and ruthenium complex as the signal-producing compound. The ECL-based DNA biosensor was fabricated by self-assembling the ECL probe of thiolated hairpin DNA tagged with ruthenium complex on the surface of a gold electrode. In the absence of target ss-DNA, the ECL probe immobilized on the surface of the electrode was in the folded configuration in which its termini were held in close proximity to the electrode, and thus a strong ECL signal could be generated. In the presence of target ss-DNA, a stem-loop of the ECL probe on the electrode was converted into a linear double-helix configuration due to hybridization, resulting in the tag moving away from the electrode surface, which in turn decreased the ECL signal. The ECL intensity of the DNA biosensor generated a "switch off" mode, which decreased with an increase of the concentration of target DNA, and a detection limit of 9 x 10(-11) M complementary target ss-DNA was achieved. Single mismatched target ss-DNA was effectively discriminated from complementary target ss-DNA. The effect of different loop lengths of the hairpin DNA on the selectivity of the ECL DNA biosensor has been investigated. This work demonstrated that the sensitivity and specificity of an ECL DNA biosensor could be greatly improved using a hairpin DNA species which has an appropriate stem and loop length as the recognition element.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathews, D. H., Sabina, J., Zuker, M., & Turner, D. H. (1999) · Journal of Molecular Biology · doi:10.1006/jmbi.1999.2700 · Cited by 3,795
Cited by
Applications and trends in electrochemiluminescence
Hu, L., & Xu, G. (2010) · Chemical Society Reviews · doi:10.1039/b923679c · Cited by 1,104
Gold nanorod-based localized surface plasmon resonance biosensors: A review
Cao, J., Sun, T., & Grattan, K. T. V. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.056 · Cited by 768
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
TELES, F., & FONSECA, L. (2008) · Talanta · doi:10.1016/j.talanta.2008.07.024 · Cited by 405
Smartphone Fluorescence Spectroscopy
Yu, H., Tan, Y., & Cunningham, B. T. (2014) · Analytical Chemistry · doi:10.1021/ac502080t · Cited by 281
Metadata
- Authors
- Zhang, J., Qi, H., Li, Y., Yang, J., Gao, Q., & Zhang, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-03-14
- Volume
- 80
- Issue
- 8
- Pages
- 2888-2894
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1964051406
- Cited by
- 196
- References
- 1
- FWCI
- 9.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.