Gel-Eluted Liquid Fraction Entrapment Electrophoresis: An Electrophoretic Method for Broad Molecular Weight Range Proteome Separation
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Although well-established as a technique for protein purification, the application of continuous elution tube gel electrophoresis to proteome fractionation remains problematic. Difficulties associated with sample collection, particularly at the high mass range or at low sample loadings, continue to plague the technique. Furthermore, an upper mass limit is imposed as slow-moving higher molecular weight proteins are progressively diluted during the collection phase. In short, with current technology, effective separation over a broad mass range has not been achieved. In this work, we present improved techniques for continuous elution tube gel electrophoresis to accommodate broad mass range separation of proteins. Our device enables rapid partitioning of a proteome into discrete mass range fractions in the solution phase. High recovery is achieved at submicrogram to milligram sample loadings. We demonstrate comprehensive, reproducible separations of protein mixtures, as well as separation of a proteome in as fast as 1 h, over mass ranges from below 10 to 250 kDa. Finally, we identified proteins from a prefractionated standard protein mixture using liquid chromatography tandem mass spectrometric (LC-MS/MS) analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Size-based protein fractionation is essential to separate the larger proteins from the smaller ones for the top-down MS analysis of large proteins (47, 48).”
From Distinct hypertrophic cardiomyopathy genotypes result in convergent sarcomeric proteoform profiles revealed by top-down proteomics (2020) · cites this paper as [47]
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,995
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Wessel, D., & Flügge, U. I. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90782-6 · Cited by 4,028
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605
An apparatus for preparative temperature-regulated polyacrylamide gel electrophoresis
Jovin, T., Chrambach, A., & Naughton, M. A. (1964) · Analytical Biochemistry · doi:10.1016/0003-2697(64)90192-7 · Cited by 602
A high-quality catalog of the Drosophila melanogaster proteome
Brunner, E., Ahrens, C. H., Mohanty, S., Baetschmann, H., Loevenich, S., Potthast, F., Deutsch, E. W., Panse, C., de Lichtenberg, U., Rinner, O., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1300 · Cited by 276
Two-dimensional liquid separations–mass mapping of proteins from human cancer cell lysates
Lubman, D. M., Kachman, M. T., Wang, H., Gong, S., Yan, F., Hamler, R. L., O’Neil, K. A., Zhu, K., Buchanan, N. S., & Barder, T. J. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00551-2 · Cited by 110
Lewis, U. J., & Clark, M. O. (1963) · Analytical Biochemistry · doi:10.1016/0003-2697(63)90154-4 · Cited by 109
Research works printed but not linked: 11
- Gorg A., 2004, J. Proteomics, 4, 3685
- Gygi S. P., 2000, Proc. Natl. Acad. Sci. U.S.A., 97, 9395
- Shi Y., 2004, J. Chromatogr., A, 1053, 36
- Pal M., 2006, Anal. Chem., 78, 710
- Opiteck G. J., 1997, J. Anal. Chem., 69, 2291
- Hou W. M., 2007, Anal. Chem., 79, 44
- Rabilloud T., 2002, Proteomics, 2, 10
- Davidsson P., 1999, Biochim. Biophys. Acta, 1473, 399
- Meng F. Y., 2002, Anal. Chem., 74, 2929
- Du Y., 2004, J. Proteome Res., 3, 806
- Pincet F., 1995, Langmuir, 11, 1235
Cited by
Items 201–210 of 210
Spectral Deconvolution, Feature Detection, and Proteoform Identification for Top-Down Proteomics
Basharat, A. R. (2024) · IUScholarWorks (Indiana University) · doi:10.7912/4jm0-9402
Caractérisation du système microtubulaire par analyse top-down et protéomique d'affinité
Calligaris, D. (2011) · theses.fr (ABES) · doi:10.70675/b01c0bc4zcec4z4ba5z8313z533703831e2d
Isolation and characterization of hyperthermophilic archaeal virus-host systems
Rensen, E. (2016) · theses.fr (ABES) · doi:10.70675/e6462b5az81f0z4cbczb37dz7340c1cd7211
Clinical Proteomics Applied to Food Allergy
Stryiński, R., Abril, A. G., Mateos, J., & Carrera, M. (2026) · Advances in experimental medicine and biology · doi:10.1007/978-3-032-18966-0_20
Protein Aggregation Capture for Top-Down Proteomics
Feltenstein, I. G., & Drown, B. (2026) · Journal of Proteome Research · doi:10.64898/2026.07.02.736076
“37,38 Although broadly used, this approach is technically challenging to execute with limited sample input and is not amenable to automation.”
Electrokinetic Removal of Sodium Dodecyl Sulfate from Proteins for Mass Spectrometry Analysis
Jakubec, P. J. (2021) · DalSpace (Dalhousie University)
Targeted Analysis of >1500 Plasma Proteoforms via Individual Ion Mass Spectrometry
Sánchez, A., Plá, I., Peterson, K. N., White, V., Fisher, T. D., Hollas, M. A. R., Su, T., Le, N. H. V., Harrington, C., Cravedi, P., et al. (2026) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6c00449
Comprehensive Online Two-Dimensional nanoLCxCZE-MS for Deep Top-Down Proteomics
Waldmann, T., Kaulich, P. T., Tholey, A., & Neusüß, C. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c05035
Metadata
- Authors
- Tran, J. C., & Doucette, A. A.
- Affiliations
- Dalhousie University (CA)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-01-30
- Volume
- 80
- Issue
- 5
- Pages
- 1568-1573
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2009278096
- Cited by
- 206
- References
- 22
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 6 · 2023: 10 · 2022: 6 · 2021: 8 · 2020: 15 · 2019: 12 · 2018: 10 · 2017: 22 · 2016: 14 · 2015: 10 · 2014: 9 · 2013: 15 · 2012: 16
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dalhousie University
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- high molecular weight proteins, protein separation, sample loading capacity, protein identification
- MeSH terms
- Bacillus subtilis, Bacterial Proteins, Electrophoresis, Reproducibility of Results, Proteome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.