Quantification of NTproBNP in Rat Serum Using Immunoprecipitation and LC/MS/MS: a Biomarker of Drug-Induced Cardiac Hypertrophy
The DOI matches its Crossref record.
Abstract
Brain natriuretic peptide (BNP) and N-terminal proBNP (NTproBNP) are well established in the clinic as biomarkers of heart failure. BNP hormone and the inactive NTproBNP are predominantly secreted in the ventricles of the heart in response to pressure overload and, consequently, are being investigated as markers of drug-induced cardiac hypertrophy in rat to support drug development. In the work presented here, an immunoaffinity-based LC/MS/MS assay was developed and validated to measure a selective tryptic fragment of NTproBNP in rat serum. The assay covers the range of 13-329 pg/mL of the tryptic fragment LLELIR, corresponding to 0.1-2.5 ng/mL intact NTproBNP. A stable isotope-labeled version of NTproBNP containing the tryptic fragment LLELI[13C615N1]R was prepared by solid-phase peptide synthesis and was used as an internal standard to minimize assay variability. Due to endogenous NTproBNP present in rat serum, human serum was used as the control matrix, and parallelism between rat and human serum was established by standard addition. Assay accuracy (% RE) and precision (% CV) were measured at three concentrations on each of 4 days and did not exceed 4.2 and 14.5%, respectively. Additionally, study data are presented from the application of this assay in which rats demonstrated a significant increase in NTproBNP serum concentration following administration of an agent known to induce cardiac hypertrophy. In this study, the relationship between serum NTproBNP and cardiac hypertrophy was corroborated by increases in heart weight and magnetic resonance imaging of the test subjects' left ventricle. To our knowledge, this represents the first reported assay for NTproBNP in preclinical species for the assessment of cardiac hypertrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Carr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Self-citationQuantitative analysis of peptides and proteins in biomedicine by targeted mass spectrometry
Gillette, M. A., & Carr, S. A. (2013) · Nature Methods · doi:10.1038/nmeth.2309 · Cited by 495
Keshishian, H., Addona, T., Burgess, M., Mani, D. R., Shi, X., Kuhn, E., Sabatine, M. S., Gerszten, R. E., & Carr, S. A. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900140-mcp200 · Cited by 286
Kuhn, E., Addona, T., Keshishian, H., Burgess, M., Mani, D. R., Lee, R. T., Sabatine, M. S., Gerszten, R. E., & Carr, S. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.123935 · Cited by 247
Metadata
- Authors
- Berna, M., Ott, L., Engle, S., Watson, D., Solter, P., & Ackermann, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-01-08
- Volume
- 80
- Issue
- 3
- Pages
- 561-566
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2056730778
- Cited by
- 69
- References
- 0
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of NTproBNP in Rat Serum Using Immunoprecipitation and LC/MS/MS: a Biomarker of Drug-Induced Cardiac Hypertrophy. https://app.cochat.ai/papers/10.1021/ac702311m
- The paper
- Berna, M., Ott, L., Engle, S., Watson, D., Solter, P., & Ackermann, B. (2008). Quantification of NTproBNP in Rat Serum Using Immunoprecipitation and LC/MS/MS: a Biomarker of Drug-Induced Cardiac Hypertrophy. Analytical Chemistry. https://doi.org/10.1021/ac702311m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.