The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Towards Absolute Quantification of Therapeutic Monoclonal Antibody in Serum by LC−MS/MS Using Isotope-Labeled Antibody Standard and Protein Cleavage Isotope Dilution Mass Spectrometry
Abstract
Although LC-MS methods are increasingly used for the absolute quantification of proteins, the lack of appropriate internal standard (IS) hinders the development of rapid and standardized analytical methods for both in vitro and in vivo studies. Here, we have developed a novel method for the absolute quantification of a therapeutic protein, which is monoclonal antibody (mAb). The method combines liquid chromatography tandem mass spectrometry (LC-MS/MS) and protein cleavage isotope dilution mass spectrometry with the isotope-labeled mAb as IS. The latter was identical to the analyzed mAb with the exception that each threonine contains four (13)C atoms and one (15)N atom. Serum samples were spiked with IS prior to the overnight trypsin digestion and subsequent sample cleanup. Sample extracts were analyzed on a C18 ACE column (150 mm x 4.6 mm) using an LC gradient time of 11 min. Endogenous mAb concentrations were determined by calculating the peak height ratio of its signature peptide to the corresponding isotope-labeled peptide. The linear dynamic range was established between 5.00 and 1000 microg/mL mAb with accuracy and precision within +/-15% at all concentrations and below +/-20% at the LLOQ (lower limit of quantification). The overall method recovery in terms of mAb was 14%. The losses due to sample preparation (digestion and purification) were 72% from which about 32% was due to the first step of the method, the sample digestion. This huge loss during sample preparation strongly emphasizes the necessity to employ an IS right from the beginning. Our method was successfully applied to the mAb quantification in marmoset serum study samples, and the precision obtained on duplicate samples was, in most cases, below 20%. The comparison with enzyme-linked immunosorbent assay (ELISA) showed higher exposure in terms of AUC and Cmax with the LC-MS/MS method. Possible reasons for this discrepancy are discussed in this study. The results of this study indicate that our LC-MS/MS method is a simple, rapid, and precise approach for the therapeutic mAb quantification to support preclinical and clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barr, J. R., Maggio, V. L., Patterson, D. G., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., & Sampson, E. J. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1676 · Cited by 347
Kay, R. G., Gregory, B., Grace, P. B., & Pleasance, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3130 · Cited by 119
Cited by
Deuterium‐ and Tritium‐Labelled Compounds: Applications in the Life Sciences
Atzrodt, J., Derdau, V., Kerr, W. J., & Reid, M. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201704146 · Cited by 810
Characterization of Therapeutic Antibodies and Related Products
Beck, A., Wagner-Rousset, E., Ayoub, D., Van Dorsselaer, A., & Sanglier-Cianférani, S. (2013) · Analytical Chemistry · doi:10.1021/ac3032355 · Cited by 587
Vidova, V., & Spacil, Z. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.059 · Cited by 352
Isotope dilution strategies for absolute quantitative proteomics
Brun, V., Masselon, C., Garin, J., & Dupuis, A. (2009) · Journal of Proteomics · doi:10.1016/j.jprot.2009.03.007 · Cited by 316
Lee, J. W., Kelley, M., King, L. E., Yang, J., Salimi-Moosavi, H., Tang, M. T., Lu, J.-F., Kamerud, J., Ahene, A., Myler, H., et al. (2011) · The AAPS Journal · doi:10.1208/s12248-011-9251-3 · Cited by 270
Recommendations for Validation of LC-MS/MS Bioanalytical Methods for Protein Biotherapeutics
Jenkins, R., Duggan, J. X., Aubry, A.-F., Zeng, J., Lee, J. W., Cojocaru, L., Dufield, D., Garofolo, F., Kaur, S., Schultz, G. A., et al. (2015) · The AAPS Journal · doi:10.1208/s12248-014-9685-5 · Cited by 181
Metadata
- Authors
- Heudi, O., Barteau, S., Zimmer, D., Schmidt, J., Bill, K., Lehmann, N., Bauer, C., & Kretz, O.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-05-09
- Volume
- 80
- Issue
- 11
- Pages
- 4200-4207
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2025186347
- Cited by
- 231
- References
- 2
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.