Isotopic Peak Intensity Ratio Based Algorithm for Determination of Isotopic Clusters and Monoisotopic Masses of Polypeptides from High-Resolution Mass Spectrometric Data
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Determining isotopic clusters and their monoisotopic masses is a first step in interpreting complex mass spectra generated by high-resolution mass spectrometers. We propose a mathematical model for isotopic distributions of polypeptides and an effective interpretation algorithm. Our model uses two types of ratios: intensity ratio of two adjacent peaks and intensity ratio product of three adjacent peaks in an isotopic distribution. These ratios can be approximated as simple functions of a polypeptide mass, the values of which fall within certain ranges, depending on the polypeptide mass. Given a spectrum as a peak list, our algorithm first finds all isotopic clusters consisting of two or more peaks. Then, it scores clusters using the ranges of ratio functions and computes the monoisotopic masses of the identified clusters. Our method was applied to high-resolution mass spectra obtained from a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer coupled to reverse-phase liquid chromatography (RPLC). For polypeptides whose amino acid sequences were identified by tandem mass spectrometry (MS/MS), we applied both THRASH-based software implementations and our method. Our method was observed to find more masses of known peptides when the numbers of the total clusters identified by both methods were fixed. Experimental results show that our method performed better for isotopic mass clusters of weak intensity where the isotopic distributions deviate significantly from their theoretical distributions. Also, it correctly identified some isotopic clusters that were not found by THRASH-based implementations, especially those for which THRASH gave 1 Da mismatches. Another advantage of our method is that it is very fast, much faster than THRASH that calculates the least-squares fit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451
Cited by
Deconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
Guner, H., Close, P. L., Cai, W., Zhang, H., Peng, Y., Gregorich, Z. R., & Ge, Y. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0789-4 · Cited by 73
Mass Spectrometric Analysis of Histone Proteoforms
Yuan, Z.-F., Arnaudo, A. M., & Garcia, B. A. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-015959 · Cited by 64
Metadata
- Authors
- Park, K., Yoon, J. Y., Lee, S., Paek, E., Park, H., Jung, H.-J., & Lee, S.-W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-28
- Volume
- 80
- Issue
- 19
- Pages
- 7294-7303
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010548624
- Cited by
- 36
- References
- 2
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Isotopic Peak Intensity Ratio Based Algorithm for Determination of Isotopic Clusters and Monoisotopic Masses of Polypeptides from High-Resolution Mass Spectrometric Data. https://app.cochat.ai/papers/10.1021/ac800913b
- The paper
- Park, K., Yoon, J. Y., Lee, S., Paek, E., Park, H., Jung, H.-J., & Lee, S.-W. (2008). Isotopic Peak Intensity Ratio Based Algorithm for Determination of Isotopic Clusters and Monoisotopic Masses of Polypeptides from High-Resolution Mass Spectrometric Data. Analytical Chemistry. https://doi.org/10.1021/ac800913b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.