Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Aptamer-Based Au Nanoparticles-Enhanced Surface Plasmon Resonance Detection of Small Molecules

Wang, Jianlong, Zhou, H. Susan·2008·Analytical Chemistry

Abstract

Small molecules are difficult to detect by conventional SPR technique directly because the changes in the refractive index resulting from the binding processes of small biomolecules are often small. In order to extend the application of SPR biosensor in detecting a small molecule, we combine the advantage of aptamer technique with the amplifying effect of Au nanoparticles to design a sensitive SPR sensor for detecting small molecules. The principle of this sensor is based on surface inhibition detection. The aptamer is first immobilized on SPR gold film with its ss-DNA structure. The aptamer possessing this structure can be hybridized with Au nanoparticles-tagged complementary ss-DNA and result in a large change of SPR signal. However, the aptamer will change its structure from ss-DNA to tertiary structure after adenosine is added to the SPR cell. The aptamer possessing tertiary structure could not hybridize with Au nanoparticles-tagged complementary ss-DNA. Thus, the change of SPR signal resulted in the hybridization reaction between aptamer and Au nanoparticles-tagged complementary ss-DNA will decrease with the increase of the number of aptamers possessing tertiary structure, which is proportional to the concentration of the small molecule. Based on this principle, we choose a simple system (antiadenosine aptamer/adenosine) to detect the sensing ability of this SPR biosensor for a small molecule. The experimental results confirm that the SPR sensor we developed possesses a good sensitivity and a high selectivity for adenosine. The detection range for adenosine is from 1 x 10 (-9) to 1 x 10 (-6) M. More significantly, it is fairly easy to generalize this strategy to detect a spectrum of small molecules by SPR spectroscopy using different aptamers. Therefore, it is expected that this method may offer a new direction in designing high-performance SPR biosensors for sensitive and selective detection of a wide spectrum of small molecules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac801281c

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Wang, J., & Zhou, H. S.
Venue
Analytical Chemistry
Published
2008-08-16
Volume
80
Issue
18
Pages
7174-7178
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2052032121
Cited by
185
References
1
FWCI
7.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.