Quadrupole-Time-of-Flight Mass Spectrometer Modified for Higher-Energy Dissociation Reduces Protein Assemblies to Peptide Fragments
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The gas-phase dissociation of protein assemblies is becoming crucial for the application of mass spectrometry to structural biology. However certain aspects of the dissociation mechanism remain elusive. Moreover, many protein complexes resist dissociation at the energies accessible with current instrumentation. Here we report new insights into the collision-induced dissociation mechanism of protein assemblies. By holding activation energy constant and varying the charge state of the precursor ion, we show that the total charge of the precursor ion dramatically influences the internal energy required to dissociate monomers from the protein assembly. Furthermore, we have developed a modified quadrupole-time-of-flight instrument capable of accessing activation energies higher than previously possible. Under these conditions, protein assemblies eject subunits with excess internal energy that subsequently fragment into peptides. Together, these data indicate that the non-covalent dissociation is limited by the amount of charge available and not merely the activation energy, and they project the exciting possibility of extracting sequence information directly from intact protein complexes in the gas phase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Self-citationDecoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Cited by
Ultraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules
Brodbelt, J. S., Morrison, L. J., & Santos, I. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00440 · Cited by 295
Mass spectrometry: come of age for structural and dynamical biology
Benesch, J. L., & Ruotolo, B. T. (2011) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2011.08.002 · Cited by 264
Self-citationBelov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175
Snijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168
Konijnenberg, A., Bannwarth, L., Yilmaz, D., Koçer, A., Venien‐Bryan, C., & Sobott, F. (2015) · Protein Science · doi:10.1002/pro.2703 · Cited by 45
Self-citation
Metadata
- Authors
- Benesch, J. L. P., Ruotolo, B. T., Sobott, F., Wildgoose, J., Gilbert, A., Bateman, R., & Robinson, C. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-12-23
- Volume
- 81
- Issue
- 3
- Pages
- 1270-1274
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2074901150
- Cited by
- 60
- References
- 2
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quadrupole-Time-of-Flight Mass Spectrometer Modified for Higher-Energy Dissociation Reduces Protein Assemblies to Peptide Fragments. https://app.cochat.ai/papers/10.1021/ac801950u
- The paper
- Benesch, J. L. P., Ruotolo, B. T., Sobott, F., Wildgoose, J., Gilbert, A., Bateman, R., & Robinson, C. V. (2009). Quadrupole-Time-of-Flight Mass Spectrometer Modified for Higher-Energy Dissociation Reduces Protein Assemblies to Peptide Fragments. Analytical Chemistry. https://doi.org/10.1021/ac801950u
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.