Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 308

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Highly Sensitive Immunoassay of Lung Cancer Marker Carcinoembryonic Antigen Using Surface-Enhanced Raman Scattering of Hollow Gold Nanospheres

Chon, Hyangah, Lee, Sangyeop, Son, Sang Wook, Oh, Chil Hwan, Choo, Jaebum·2009·Analytical Chemistry

Abstract

A quick and reproducible surface-enhanced Raman scattering (SERS)-based immunoassay technique, using hollow gold nanospheres (HGNs) and magnetic beads, has been developed. Here, HGNs show strong enhancement effects from individual particles because hot spots can be localized on the pinholes in the hollow particle structure. Thus, HGNs can be used for highly reproducible immunoanalysis of cancer markers. Magnetic beads were used as supporting substrates for the formation of the immunocomplex. This SERS-based immunoassay technique overcomes the problem of slow immunoreaction caused by the diffusion-limited kinetics on a solid substrate because all of the reactions occur in solution. For the validation of our SERS immunoassay, a well-known lung cancer marker, carcinoembryonic antigen (CEA), was used as a target marker. According to our experimental results, the limit of detection (LOD) was determined to be 1-10 pg/mL, this value being about 100-1000 times more sensitive than the LOD of enzyme-linked immunosorbent assay. Furthermore, the assay time took less than 1 h, including washing and optical detection steps.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac802722c

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 308

Metadata

Authors
Chon, H., Lee, S., Son, S. W., Oh, C. H., & Choo, J.
Venue
Analytical Chemistry
Published
2009-03-20
Volume
81
Issue
8
Pages
3029-3034
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2032972108
Cited by
308
References
19
FWCI
8.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.