The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Nanoholes As Nanochannels: Flow-through Plasmonic Sensing
Abstract
We combine nanofluidics and nanoplasmonics for surface-plasmon resonance (SPR) sensing using flow-through nanohole arrays. The role of surface plasmons on resonant transmission motivates the application of nanohole arrays as surface-based biosensors. Research to date, however, has focused on dead-ended holes, and therefore failed to harness the benefits of nanoconfined transport combined with SPR sensing. The flow-through format enables rapid transport of reactants to the active surface inside the nanoholes, with potential for significantly improved time of analysis and biomarker yield through nanohole sieving. We apply the flow-through method to monitor the formation of a monolayer and the immobilization of an ovarian cancer biomarker specific antibody on the sensing surface in real-time. The flow-through method resulted in a 6-fold improvement in response time as compared to the established flow-over method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Extraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Genet, C., & Ebbesen, T. W. (2007) · Nature · doi:10.1038/nature05350 · Cited by 2,007
Charge- and size-based separation of macromolecules using ultrathin silicon membranes
Striemer, C. C., Gaborski, T. R., McGrath, J. L., & Fauchet, P. M. (2007) · Nature · doi:10.1038/nature05532 · Cited by 753
A New Generation of Sensors Based on Extraordinary Optical Transmission
Gordon, R., Sinton, D., Kavanagh, K. L., & Brolo, A. G. (2008) · Accounts of Chemical Research · doi:10.1021/ar800074d · Cited by 520
Self-citationKarpovich, D. S., & Blanchard, G. J. (1994) · Langmuir · doi:10.1021/la00021a066 · Cited by 485
Evanescently coupled resonance in surface plasmon enhanced transmission
Krishnan, A., Thio, T., Kim, T. J., Lezec, H. J., Ebbesen, T. W., Wolff, P. A., Pendry, J. B., Martín-Moreno, L., & García-Vidal, F. J. (2001) · Optics Communications · doi:10.1016/s0030-4018(01)01558-9 · Cited by 478
In Situ Kinetics of Self-Assembly by Surface Plasmon Resonance Spectroscopy
Peterlinz, K. A., & Georgiadis, R. (1996) · Langmuir · doi:10.1021/la9508452 · Cited by 461
Cited by
De Angelis, F., Gentile, F., Mecarini, F., Das, G., Moretti, M., Candeloro, P., Coluccio, M. L., Cojoc, G., Accardo, A., Liberale, C., et al. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.222 · Cited by 736
Ultrasensitive surface-enhanced Raman scattering detection in common fluids
Yang, S., Dai, X., Stogin, B. B., & Wong, T.-S. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1518980113 · Cited by 704
SPR Biosensors: Historical Perspectives and Current Challenges
Singh, P. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.01.118 · Cited by 608
Engineering metallic nanostructures for plasmonics and nanophotonics
Lindquist, N. C., Nagpal, P., McPeak, K. M., Norris, D. J., & Oh, S.-H. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/3/036501 · Cited by 497
Optical Biosensors Based on Plasmonic Nanostructures: A Review
Spackova, B., Wrobel, P., Bockova, M., & Homola, J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2624340 · Cited by 421
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
LSPR Chip for Parallel, Rapid, and Sensitive Detection of Cancer Markers in Serum
Aćimović, S. S., Ortega, M. A., Sanz, V., Berthelot, J., Garcia-Cordero, J. L., Renger, J., Maerkl, S. J., Kreuzer, M. P., & Quidant, R. (2014) · Nano Letters · doi:10.1021/nl500574n · Cited by 310
New trends in instrumental design for surface plasmon resonance-based biosensors
Abbas, A., Linman, M. J., & Cheng, Q. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.030 · Cited by 301
Trends and challenges of refractometric nanoplasmonic biosensors: A review
Estevez, M.-C., Otte, M. A., Sepulveda, B., & Lechuga, L. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.048 · Cited by 301
Nanoplasmonic sensors for biointerfacial science
Jackman, J. A., Rahim Ferhan, A., & Cho, N.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00494f · Cited by 258
Koya, A. N., Zhu, X., Ohannesian, N., Yanik, A. A., Alabastri, A., Proietti Zaccaria, R., Krahne, R., Shih, W.-C., & Garoli, D. (2021) · ACS Nano · doi:10.1021/acsnano.0c10945 · Cited by 257
High-sensitivity nanophotonic sensors with passive trapping of analyte molecules in hot spots
Miao, X., Yan, L., Wu, Y., & Liu, P. Q. (2021) · Light: Science & Applications · doi:10.1038/s41377-020-00449-7 · Cited by 71
Metadata
- Authors
- Eftekhari, F., Escobedo, C., Ferreira, J., Duan, X., Girotto, E. M., Brolo, A. G., Gordon, R., & Sinton, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-05-01
- Volume
- 81
- Issue
- 11
- Pages
- 4308-4311
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2064765974
- Cited by
- 290
- References
- 16
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.