The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
New trends in instrumental design for surface plasmon resonance-based biosensors
Open accessAbstract
Surface plasmon resonance (SPR)-based biosensing is one of the most advanced label free, real time detection technologies. Numerous research groups with divergent scientific backgrounds have investigated the application of SPR biosensors and studied the fundamental aspects of surface plasmon polaritons that led to new, related instrumentation. As a result, this field continues to be at the forefront of evolving sensing technology. This review emphasizes the new developments in the field of SPR-related instrumentation including optical platforms, chips design, nanoscale approach and new materials. The current tendencies in SPR-based biosensing are identified and the future direction of SPR biosensor technology is broadly discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Experimental Verification of a Negative Index of Refraction
Shelby, R. A., Smith, D. R., & Schultz, S. (2001) · Science · doi:10.1126/science.1058847 · Cited by 8,347
Extraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Localized Surface Plasmon Resonance Spectroscopy and Sensing
Willets, K. A., & Van Duyne, R. P. (2007) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.58.032806.104607 · Cited by 6,171
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by Light
Kretschmann, E., & Raether, H. (1968) · Zeitschrift für Naturforschung A · doi:10.1515/zna-1968-1247 · Cited by 3,377
Mimicking Surface Plasmons with Structured Surfaces
Pendry, J. B., Martín-Moreno, L., & Garcia-Vidal, F. J. (2004) · Science · doi:10.1126/science.1098999 · Cited by 3,276
Otto, A. (1968) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01391532 · Cited by 3,065
Cited by
Surface Plasmon Resonance (SPR) Biosensors in Pharmaceutical Analysis
Olaru, A., Bala, C., Jaffrezic-Renault, N., & Aboul-Enein, H. Y. (2015) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.881250 · Cited by 400
Nanoplasmonic sensors for biointerfacial science
Jackman, J. A., Rahim Ferhan, A., & Cho, N.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00494f · Cited by 258
Metadata
- Authors
- Abbas, A., Linman, M. J., & Cheng, Q.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 26
- Issue
- 5
- Pages
- 1815-1824
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2069190985
- Cited by
- 301
- References
- 54
- FWCI
- 12.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New trends in instrumental design for surface plasmon resonance-based biosensors. https://app.cochat.ai/papers/10.1016/j.bios.2010.09.030
- The paper
- Abbas, A., Linman, M. J., & Cheng, Q. (2011). New trends in instrumental design for surface plasmon resonance-based biosensors. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2010.09.030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.