The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Three-Dimensional Imaging of Metabolites in Tissues under Ambient Conditions by Laser Ablation Electrospray Ionization Mass Spectrometry
Abstract
Three-dimensional (3D) imaging of molecular distributions offers insight into the correlation between biochemical processes and the spatial organization of a biological tissue. Simultaneous identification of diverse molecules is a virtue of mass spectrometry (MS) that in combination with ambient ion sources enables the atmospheric pressure investigation of biomolecular distributions and processes. Here, we report on the development of an MS-based technique that allows 3D chemical imaging of tissues under ambient conditions without sample preparation. The method utilizes laser ablation electrospray ionization (LAESI) for direct molecular imaging with lateral and depth resolutions of approximately 300 microm and 30-40 microm, respectively. We demonstrate the feasibility of LAESI 3D imaging MS of metabolites in the leaf tissues of Peace lily (Spathiphyllum lynise) and the variegated Zebra plant (Aphelandra squarrosa). Extensive tandem MS studies help with the structure identification of the metabolites. The 3D distributions are found to exhibit tissue-specific metabolite accumulation patterns that correlate with the biochemical roles of these chemical species in plant defense and photosynthesis. Spatial correlation coefficients between the intensity distributions of different ions help to identify colocalization of metabolites and potentially uncover connections between metabolic pathways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Cited by
Global metabolic profiling of animal and human tissues via UPLC-MS
Want, E. J., Masson, P., Michopoulos, F., Wilson, I. D., Theodoridis, G., Plumb, R. S., Shockcor, J., Loftus, N., Holmes, E., & Nicholson, J. K. (2013) · Nature Protocols · doi:10.1038/nprot.2012.135 · Cited by 1,611
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
Sumner, L. W., Lei, Z., Nikolau, B. J., & Saito, K. (2015) · Natural Product Reports · doi:10.1039/c4np00072b · Cited by 233
Metadata
- Authors
- Nemes, P., Barton, A. A., & Vertes, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-02
- Volume
- 81
- Issue
- 16
- Pages
- 6668-6675
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2049123051
- Cited by
- 223
- References
- 1
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional Imaging of Metabolites in Tissues under Ambient Conditions by Laser Ablation Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac900745e
- The paper
- Nemes, P., Barton, A. A., & Vertes, A. (2009). Three-Dimensional Imaging of Metabolites in Tissues under Ambient Conditions by Laser Ablation Electrospray Ionization Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac900745e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.