The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Protein Hydrogen Exchange Measured at Single-Residue Resolution by Electron Transfer Dissociation Mass Spectrometry
Abstract
Because of unparalleled sensitivity and tolerance to protein size, mass spectrometry (MS) has become a popular method for measuring the solution hydrogen (1H/2H) exchange (HX) of biologically relevant protein states. While incorporated deuterium can be localized to different regions by pepsin proteolysis of the labeled protein, the assignment of deuteriums to individual residues is typically not obtained, thereby limiting a detailed understanding of HX and the dynamics of protein structure. Here we use gas-phase fragmentation of peptic peptides by electron transfer dissociation (ETD) to measure the HX of individual amide linkages in the amyloidogenic protein beta2-microglobulin. A comparison of the deuterium levels of 60 individual backbone amides of beta2-microglobulin measured by HX-ETD-MS analysis to the corresponding values measured by NMR spectroscopy shows an excellent correlation. The deuterium labeling pattern of beta2-microglobulin is retained in the gaseous fragment ions by employing mild declustering conditions for electrospray ionization. A recently developed model peptide is used to arrive at such ion source declustering conditions that prevent the occurrence of intramolecular gas-phase hydrogen (1H/2H) migration (i.e., hydrogen scrambling). This article demonstrates that ETD can be implemented in a mass spectrometric method to monitor the conformational dynamics of proteins in solution at single-residue resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Key interactions in HIV-1 maturation identified by hydrogen-deuterium exchange
Lanman, J., Lam, T. T., Emmett, M. R., Marshall, A. G., Sakalian, M., & Prevelige, P. E. (2004) · Nature Structural & Molecular Biology · doi:10.1038/nsmb790 · Cited by 164
Cited by
Hydrogen exchange mass spectrometry for studying protein structure and dynamics
Konermann, L., Pan, J., & Liu, Y.-H. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00113a · Cited by 838
Masson, G. R., Burke, J. E., Ahn, N. G., Anand, G. S., Borchers, C., Brier, S., Bou-Assaf, G. M., Engen, J. R., Englander, S. W., Faber, J., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0459-y · Cited by 729
Self-citationAnalytical tools for characterizing biopharmaceuticals and the implications for biosimilars
Berkowitz, S. A., Engen, J. R., Mazzeo, J. R., & Jones, G. B. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3746 · Cited by 529
Differential hydrogen/deuterium exchange mass spectrometry analysis of protein–ligand interactions
Chalmers, M. J., Busby, S. A., Pascal, B. D., West, G. M., & Griffin, P. R. (2011) · Expert Review of Proteomics · doi:10.1586/epr.10.109 · Cited by 252
Wei, H., Mo, J., Tao, L., Russell, R. J., Tymiak, A. A., Chen, G., Iacob, R. E., & Engen, J. R. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.07.019 · Cited by 208
Ion Activation Methods for Peptides and Proteins
Macias, L. A., Santos, I. C., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04859 · Cited by 107
Huang, R. Y.-C., Garai, K., Frieden, C., & Gross, M. L. (2011) · Biochemistry · doi:10.1021/bi2010027 · Cited by 97
Metadata
- Authors
- Rand, K. D., Zehl, M., Jensen, O. N., & Jørgensen, T. J. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-06-16
- Volume
- 81
- Issue
- 14
- Pages
- 5577-5584
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1974900044
- Cited by
- 220
- References
- 2
- FWCI
- 10.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.