The DOI matches its Crossref record.
Label-Free and Multiplex Detection of Antibiotic Residues in Milk Using Imaging Surface Plasmon Resonance-Based Immunosensor
Open accessAbstract
Monitoring of antimicrobial drug residues in foods relies greatly on the availability of adequate analytical techniques. Currently, there is a need for a high-throughput screening method with a broad-spectrum detection range. This paper describes the development of a microarray biosensor, based on an imaging surface plasmon resonance (iSPR) platform, for quantitative and simultaneous immunodetection of different antibiotic residues in milk. Model compounds from four major antibiotic families: aminoglycosides (Neomycin, Gentamicin, Kanamycin, and Streptomycin), sulfonamides (Sulfamethazine), fenicols (Chloramphenicol), and fluoroquinolones (Enrofloxacin) were detected using a single sensor chip. By multiplexing seven immunoassays in a competitive format, we were able to measure all the target compounds at parts per billion (ppb) levels in buffer and in 10x-diluted milk. The assays for Neomycin, Kanamycin, Streptomycin, Enrofloxacin, and Sulfamethazine were sensitive enough for milk control at maximum residue levels as established in the European Union. The overall performance of the biosensor was determined to be comparable to that of conventional four-channel surface plasmon resonance (SPR)-based biosensors, in terms of assay sensitivity and robustness. Combining the advantages of a SPR sensor and a microarray, utilization of the biosensor described here offers a promising alternative to the existing methods and is highly relevant for multianalyte food profiling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface Plasmon Resonance (SPR) Biosensors in Pharmaceutical Analysis
Olaru, A., Bala, C., Jaffrezic-Renault, N., & Aboul-Enein, H. Y. (2015) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.881250 · Cited by 400
Fast screening methods to detect antibiotic residues in food samples
Cháfer-Pericás, C., Maquieira, Á., & Puchades, R. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.06.004 · Cited by 380
Gaudin, V. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.005 · Cited by 325
Zhang, Z., Wang, Z., Zhang, C., Yao, Z., Zhang, S., Wang, R., Tian, Z., Han, J., Chang, C., Lou, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202308453 · Cited by 309
Antibiotic residues in milk: Past, present, and future
Sachi, S., Ferdous, J., Sikder, M., & Hussani, S. (2019) · Journal of Advanced Veterinary and Animal Research · doi:10.5455/javar.2019.f350 · Cited by 296
Saei, A., Javadi, A., Afshar Mogaddam, M. R., Mirzaei, H., & Nemati, M. (2020) · Analytical Methods · doi:10.1039/d0ay01282c · Cited by 24
Metadata
- Authors
- Rebe Raz, S., Bremer, M. G. E. G., Haasnoot, W., & Norde, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-17
- Volume
- 81
- Issue
- 18
- Pages
- 7743-7749
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2036463386
- Cited by
- 165
- References
- 0
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.