Dual-Pressure Linear Ion Trap Mass Spectrometer Improving the Analysis of Complex Protein Mixtures
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The considerable progress in high-throughput proteomics analysis via liquid chromatography-electrospray ionization-tandem mass spectrometry over the past decade has been fueled to a large degree by continuous improvements in instrumentation. High-throughput identification experiments are based on peptide sequencing and are largely accomplished through the use of tandem mass spectrometry, with ion trap and trap-based instruments having become broadly adopted analytical platforms. To satisfy increasingly demanding requirements for depth of characterization and throughput, we present a newly developed dual-pressure linear ion trap mass spectrometer (LTQ Velos) that features increased sensitivity, afforded by a new source design, and demonstrates practical cycle times 2 times shorter than that of an LTQ XL, while improving or maintaining spectral quality for MS/MS fragmentation spectra. These improvements resulted in a substantial increase in the detection and identification of both proteins and unique peptides from the complex proteome of Caenorhabditis elegans, as compared to existing platforms. The greatly increased ion flux into the mass spectrometer in combination with improved isolation of low-abundance precursor ions resulted in increased detection of low-abundance peptides. These improvements cumulatively resulted in a substantially greater penetration into the baker's yeast (Saccharomyces cerevisiae) proteome compared to LTQ XL. Alternatively, faster cycle times on the new instrument allowed for higher throughput for a given depth of proteome analysis, with more peptides and proteins identified in 60 min using an LTQ Velos than in 180 min using an LTQ XL. When mass analysis was carried out with resolution in excess of 25,000 full width at half-maximum (fwhm), it became possible to isotopically resolve a small intact protein and its fragments, opening possibilities for top down experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical significance for genomewide studies
Storey, J. D., & Tibshirani, R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1530509100 · Cited by 9,692
Global analysis of protein expression in yeast
Ghaemmaghami, S., Huh, W.-K., Bower, K., Howson, R. W., Belle, A., Dephoure, N., O'Shea, E. K., & Weissman, J. S. (2003) · Nature · doi:10.1038/nature02046 · Cited by 3,750
Semi-supervised learning for peptide identification from shotgun proteomics datasets
Käll, L., Canterbury, J. D., Weston, J., Noble, W. S., & MacCoss, M. J. (2007) · Nature Methods · doi:10.1038/nmeth1113 · Cited by 2,424
Self-citationA quantitative atlas of mitotic phosphorylation
Dephoure, N., Zhou, C., Villén, J., Beausoleil, S. A., Bakalarski, C. E., Elledge, S. J., & Gygi, S. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805139105 · Cited by 1,608
Comprehensive mass-spectrometry-based proteome quantification of haploid versus diploid yeast
de Godoy, L. M. F., Olsen, J. V., Cox, J., Nielsen, M. L., Hubner, N. C., Fröhlich, F., Walther, T. C., & Mann, M. (2008) · Nature · doi:10.1038/nature07341 · Cited by 873
Large-scale phosphorylation analysis of mouse liver
Villén, J., Beausoleil, S. A., Gerber, S. A., & Gygi, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609836104 · Cited by 730
Assigning Significance to Peptides Identified by Tandem Mass Spectrometry Using Decoy Databases
Käll, L., Storey, J. D., MacCoss, M. J., & Noble, W. S. (2008) · Journal of Proteome Research · doi:10.1021/pr700600n · Cited by 607
Self-citation
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
ProLuCID: An improved SEQUEST-like algorithm with enhanced sensitivity and specificity
Xu, T., Park, S. K., Venable, J. D., Wohlschlegel, J. A., Diedrich, J. K., Cociorva, D., Lu, B., Liao, L., Hewel, J., Han, X., et al. (2015) · Journal of Proteomics · doi:10.1016/j.jprot.2015.07.001 · Cited by 511
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
A dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
“ments, has been described very recently (13).”
Self-citationEvolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Self-citationZhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Frese, C. K., Altelaar, A. F. M., Hennrich, M. L., Nolting, D., Zeller, M., Griep-Raming, J., Heck, A. J. R., & Mohammed, S. (2011) · Journal of Proteome Research · doi:10.1021/pr1011729 · Cited by 312
Andrews, G. L., Simons, B. L., Young, J. B., Hawkridge, A. M., & Muddiman, D. C. (2011) · Analytical Chemistry · doi:10.1021/ac200812d · Cited by 285
Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Wang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Kellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99
Takemori, A., Butcher, D. S., Harman, V. M., Brownridge, P., Shima, K., Higo, D., Ishizaki, J., Hasegawa, H., Suzuki, J., Yamashita, M., et al. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00303 · Cited by 90
Metadata
- Authors
- Pekar Second, T., Blethrow, J. D., Schwartz, J. C., Merrihew, G. E., MacCoss, M. J., Swaney, D. L., Russell, J. D., Coon, J. J., & Zabrouskov, V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-18
- Volume
- 81
- Issue
- 18
- Pages
- 7757-7765
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2086190383
- Cited by
- 161
- References
- 7
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.