Multiple Reaction Monitoring Cubed for Protein Quantification at the Low Nanogram/Milliliter Level in Nondepleted Human Serum
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Mass spectrometry-based strategies for the quantification of low-abundance putative protein biomarkers in human blood currently require extensive sample fractionation steps which hamper their implementation in a routine and robust way across clinical laboratories. We demonstrate that a technique using MS(3) reconstructed chromatograms on a signature of secondary ions issued from a trapped primary product ion, termed multiple reaction monitoring cubed (MRM(3)), enables targeting protein biomarkers in the low nanogram/milliliter range in nondepleted human serum. The simple two-step workflow is based on a trypsin proteolysis of whole serum (100 microL) followed by enrichment of targeted proteotypic peptides on a solid phase extraction column using mixed-cation exchange resin. MRM(3)'s fidelity of peak detection extends the dynamic range and limit of quantitation (LOQ) of protein biomarkers to the low nanogram/milliliter range, corresponding to a concentration that is 10(6)-fold lower than the concentration of the most abundant proteins in serum. The power of the MRM(3) method is illustrated by the assay of prostate specific antigen in nondepleted human sera of patients. The results correlate well with the established method for determining PSA levels in serum, i.e., enzyme-linked immunosorbent assay (ELISA) tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Barr, J. R., Maggio, V. L., Patterson, D. G., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., & Sampson, E. J. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1676 · Cited by 347
Hoofnagle, A. N., Becker, J. O., Wener, M. H., & Heinecke, J. W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.109652 · Cited by 314
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Selected reaction monitoring applied to proteomics
Gallien, S., Duriez, E., & Domon, B. (2011) · Journal of Mass Spectrometry · doi:10.1002/jms.1895 · Cited by 286
LC–MS/MS for protein and peptide quantification in clinical chemistry
Rauh, M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.030 · Cited by 171
Metadata
- Authors
- Fortin, T., Salvador, A., Charrier, J. P., Lenz, C., Bettsworth, F., Lacoux, X., Choquet-Kastylevsky, G., & Lemoine, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-10-19
- Volume
- 81
- Issue
- 22
- Pages
- 9343-9352
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1979309527
- Cited by
- 140
- References
- 4
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.