Cited by 314Advanced Proteomics Techniques and ApplicationsMass Spectrometry Techniques and ApplicationsAdvanced Biosensing Techniques and Applications

Quantification of Thyroglobulin, a Low-Abundance Serum Protein, by Immunoaffinity Peptide Enrichment and Tandem Mass Spectrometry

Open access
Hoofnagle, Andrew N, Becker, Jessica O, Wener, Mark H, Heinecke, Jay W·2008·Clinical Chemistry

Abstract

Background: Quantification of serum tumor markers plays an important role in determining whether patients treated for cancer require further therapy. Whereas large-scale proteomic efforts aim to identify novel tumor markers to facilitate early detection, optimization of methods for quantifying known tumor markers offers another approach to improving management of malignancies. For example, immunoassays used in clinical practice to measure established tumor markers suffer from potential interference from endogenous immunoglobulins and imperfect concordance across platforms—problems that also plague many other immunoassays. To address these important limitations, this study used peptide immunoaffinity enrichment in concert with liquid chromatography–tandem mass spectrometry (LC-MS/MS) to quantify thyroglobulin, a well-characterized tumor marker. Methods: We identified 3 peptides in tryptic digests of thyroglobulin that were detected at low concentrations by tandem mass spectrometry, raised polyclonal antibodies to those peptides, and used the antibodies to extract the 3 corresponding peptides from tryptic digests of human serum. We quantified each endogenous peptide using LC-MS/MS and multiple reaction monitoring with external calibrators. Results: The detection limit for endogenous thyroglobulin in serum was 2.6 μg/L (4 pmol/L). Direct comparison with immunoassay revealed good correlation (r2 = 0.81). Conclusions: Immunoaffinity peptide enrichment–tandem mass spectrometry can detect tryptic peptides of thyroglobulin at picomolar concentrations while also digesting the endogenous immunoglobulins that can potentially interfere with traditional immunoassays. Our observations suggest a general analytical strategy for using immunoaffinity isolation together with tandem mass spectrometry to quantify tumor antigens and other low-abundance proteins in human serum.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2008.109652

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 34 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Hoofnagle, A. N., Becker, J. O., Wener, M. H., & Heinecke, J. W.
Affiliations
  • Departments of Laboratory Medicine and
  • University of Washington (US)
Corresponding author
Hoofnagle, Andrew N
Venue
Clinical Chemistry
Published
2008-11-01
Volume
54
Issue
11
Pages
1796-1804
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2167033601
Cited by
314
References
34
Citations by year
2026: 2 · 2025: 9 · 2024: 12 · 2023: 13 · 2022: 9 · 2021: 10 · 2020: 16 · 2019: 9 · 2018: 16 · 2017: 21 · 2016: 25 · 2015: 15 · 2014: 28 · 2013: 26 · 2012: 31
FWCI
10.09
Type
journal article
Language
en
Open access
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
University of Washington
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
Keywords
thyroglobulin, tumor markers, immunoassay interference, polyclonal antibodies, tryptic peptides, multiple reaction monitoring, detection limit
MeSH terms
Amino Acid Sequence, Chromatography, Affinity, Chromatography, High Pressure Liquid, Humans, Immunoassay, Peptide Fragments, Peptide Mapping, Reference Standards, Sensitivity and Specificity, Thyroglobulin, Reproducibility of Results, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review