Exploring the Human Leukocyte Phosphoproteome Using a Microfluidic Reversed-Phase−TiO2−Reversed-Phase High-Performance Liquid Chromatography Phosphochip Coupled to a Quadrupole Time-of-Flight Mass Spectrometer
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The study of protein phosphorylation events is one of the most important challenges in proteome analysis. Despite the importance of phosphorylation for many regulatory processes in cells and many years of phosphoprotein and phosphopeptide research, the identification and characterization of phosphorylation by mass spectrometry is still a challenging task. Recently, we introduced an approach that facilitates the analysis of phosphopeptides by performing automated, online, TiO(2) enrichment of phosphopeptides prior to mass spectrometry (MS) analysis. The implementation of that method on a "plug-and-play" microfluidic high-performance liquid chromatography (HPLC) chip design will potentially open up efficient phosphopeptide enrichment methods enabling phosphoproteomics analyses by a broader research community. Following our initial proof of principle, whereby the device was coupled to an ion trap, we now show that this so-called phosphochip is capable of the enrichment of large numbers of phosphopeptides from complex cellular lysates, which can be more readily identified when coupled to a higher resolution quadrupole time-of-flight (Q-TOF) mass spectrometer. We use the phosphochip-Q-TOF setup to explore the phosphoproteome of nonstimulated primary human leukocytes where we identify 1012 unique phosphopeptides corresponding to 960 different phosphorylation sites providing for the first time an overview of the phosphoproteome of these important circulating white blood cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
Cited by
Kubacka, A., Diez, M. S., Rojo, D., Bargiela, R., Ciordia, S., Zapico, I., Albar, J. P., Barbas, C., Martins dos Santos, V. A. P., Fernández-García, M., et al. (2014) · Scientific Reports · doi:10.1038/srep04134 · Cited by 426
TLR4 signalling in osteoarthritis—finding targets for candidate DMOADs
Gómez, R., Villalvilla, A., Largo, R., Gualillo, O., & Herrero-Beaumont, G. (2015) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2014.209 · Cited by 230
Human Protein Reference Database and Human Proteinpedia as resources for phosphoproteome analysis
Goel, R., Harsha, H. C., Pandey, A., & Prasad, T. S. K. (2011) · Molecular BioSystems · doi:10.1039/c1mb05340j · Cited by 211
Griss, J., Perez-Riverol, Y., Lewis, S., Tabb, D. L., Dianes, J. A., del-Toro, N., Rurik, M., Walzer, M., Kohlbacher, O., Hermjakob, H., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3902 · Cited by 179
Technologies and challenges in large‐scale phosphoproteomics
Engholm‐Keller, K., & Larsen, M. R. (2013) · PROTEOMICS · doi:10.1002/pmic.201200484 · Cited by 166
Metadata
- Authors
- Raijmakers, R., Kraiczek, K., de Jong, A. P., Mohammed, S., & Heck, A. J. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-08
- Volume
- 82
- Issue
- 3
- Pages
- 824-832
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2081150154
- Cited by
- 75
- References
- 1
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.