Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Development of a Candidate Reference Measurement Procedure for the Determination of 25-Hydroxyvitamin D3 and 25-Hydroxyvitamin D2 in Human Serum Using Isotope-Dilution Liquid Chromatography−Tandem Mass Spectrometry

Open access
Tai, Susan S.-C., Bedner, Mary, Phinney, Karen W.·2010·Analytical Chemistry

Abstract

Vitamin D exists in two major forms, vitamin D(3) and vitamin D(2). Vitamin D helps the body absorb calcium and promote optimal bone health. Both forms of vitamin D are metabolized to 25-hydroxyvitamin D in the body, and the levels of 25-hydroxyvitamin D(3) [25(OH)D(3)] and 25-hydroxyvitamin D(2) [25(OH)D(2)] in serum are considered the best indicators of vitamin D status. A candidate reference measurement procedure for serum 25(OH)D(3) and 25(OH)D(2) has been developed and critically evaluated. The deuterated compounds 25(OH)D(3)-d(3) and 25(OH)D(2)-d(3) are used as internal standards for 25(OH)D(3) and 25(OH)D(2), respectively. The 25(OH)D(3) and 25(OH)D(2) and their respective labeled internal standards are simultaneously extracted from serum using liquid-liquid extraction prior to reversed-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS). Chromatographic separation was performed using a cyano (CN) column for both 25(OH)D(3) and 25(OH)D(2). Atmospheric pressure chemical ionization (APCI) in the positive ion mode and multiple reaction monitoring (MRM) were used for LC-MS/MS. The accuracy of the method was evaluated by recovery studies of measuring 25-hydroxyvitamin D [25(OH)D] in spiked samples with known 25(OH)D levels. The recoveries of the added 25(OH)D(3) and 25(OH)D(2) ranged from 99.0% to 101.0%. The absolute recoveries with this method were 97% and 92% for 25(OH)D(3) and 25(OH)D(2), respectively. Excellent precision was obtained with between-set coefficients of variation (CVs) of 0.2-0.6% for 25(OH)D levels >1 ng/g and within 2% for the level of <1 ng/g. Chromatographic separation of 25(OH)D(3) and 25(OH)D(2) from their respective isomers 3-epi-25(OH)D(3) and 3-epi-25(OH)D(2) was achieved. The limit of detection at a signal-to-noise ratio of approximately 3 was 40 pg of 25(OH)D on column (or approximately 0.15 ng/g as expressed as a concentration). This candidate reference measurement procedure for serum 25(OH)D(3) and 25(OH)D(2) demonstrates good accuracy and precision and low susceptibility to interferences. It can be used to provide an accuracy base to which clinical methods for 25(OH)D(3) and 25(OH)D(2) can be compared and that will serve as a standard of higher order for measurement traceability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9026862

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 271

Metadata

Authors
Tai, S. S.-C., Bedner, M., & Phinney, K. W.
Venue
Analytical Chemistry
Published
2010-02-05
Volume
82
Issue
5
Pages
1942-1948
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1972589180
Cited by
271
References
22
FWCI
14.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.