CoChat

Thin-Film Microbiosensors for Glucose−Lactate Monitoring

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

A miniaturized device for simultaneous measurement of glucose and lactate levels was produced by means of photopatterning of enzyme-containing photosensitive membrane precursors. This device shows no cross-talk and a lifetime for both the glucose and the lactate sensors of more than 2 weeks when continuously operated in undiluted bovine serum. Linear response ranges of up to 40 mM for glucose and 25 mM for L-lactate, in combination with 95% response times of < 30 s, were realized. The devices are mass produced by means of thin-film technology on flexible carriers to give catheter-type multisensing devices for in vivo applications. Ex vivo experiments, performed with human volunteers, where the device was continuously operated in an extracorporeal, undiluted, heparinized blood stream for 6 h, gave a correlation of r > 0.98 with respect to laboratory techniques. Subcutaneous measurements of glucose levels in pigs were close to the corresponding blood levels obtained without in vivo calibration.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac950630x

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Research works printed but not linked: 9

  1. Kimura J., 1988, Biosensors, 4, 52
  2. Tamiya E., 1989, Sens. Actuators B, 18, 307
  3. Mastrototaro J., 1991, Sens. Actuators B, 1, 145
  4. Wilke, D.; Müller, H. InTrends in electrochemical Biosensors;Costa, G., Miertus, S., Eds.; World Scientific: Singapore, 1992; pp 155−162.
  5. Trajanoski Z., Proceedings of the 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society; IEEE: Piscataway, NJ
  6. Pfeiffer E. F., 1989, Verh. Dtsch. Ges. Inn. Med., 95, 736
  7. Clarke W. L., 1984, Diabetes Care, 5, 627
  8. Varahram M., 1995, Biomed. Tech., 40, 101
  9. Ammon H. P. T., 1995, Anal. Chem., 67, 471

Cited by

Items 101–104 of 104

Metadata

Authors
Jobst, G., Moser, I., Varahram, M., Svasek, P., Aschauer, E., Trajanoski, Z., Wach, P., Kotanko, P., Skrabal, F., & Urban, G.
Affiliations
TU Wien (AT)
Venue
Analytical Chemistry
Published
1996-01-01
Volume
68
Issue
18
Pages
3173-3179
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2070038049
Cited by
102
References
20
Citations by year
2024: 1 · 2023: 2 · 2022: 4 · 2020: 5 · 2019: 5 · 2018: 5 · 2017: 4 · 2016: 2 · 2014: 5 · 2013: 2 · 2012: 3
FWCI
8.23
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • TU Graz, Internationale Beziehungen und Mobilitätsprogramme
  • Austrian Science Fund
  • Universität Wien
  • Karl-Franzens-Universität Graz
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
glucose biosensor, lactate biosensor, photopatterning, flexible substrates, sensor lifetime
MeSH terms
Adult, Animals, Blood Glucose, Electrochemistry, Female, Humans, Male, Polyhydroxyethyl Methacrylate, Swine, Biosensing Techniques, Lactic Acid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.