The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating
Abstract
A miniature, needle-type glucose sensor based on a new trilayer membrane configuration has been prepared and evaluated both in vitro and in vivo. The perfluorinated ionomer, Nafion, was used as a protective, biocompatible, outer coating, and poly(o-phenylenediamine) as an inner coating to reduce interference by small, electroactive compounds. Glucose oxidase immobilized in a bovine serum albumin matrix was sandwiched between these coatings. The entire sensor assembly of Pt working electrode and Ag/AgCl reference electrode was 0.5 mm in diameter and could be inserted subcutaneously through an 18-gauge needle. The sensor current closely followed the plasma glucose level during a glucose tolerance test in active dogs, with a delay of 3 min, corresponding to the known lag time for subcutaneous glucose levels. The sensor remained functional after 1 week of implantation, but failed after 2 weeks due to degradation of the reference electrode. In vitro tests in pH 7.4 buffer or whole blood show the sensors have good selectivity, sensitivity of about 25 nA/mM, precision of 2-5%, and a 90% response time of 33 s. Stabilization following polarization requires 10-30 min in vitro and 30-40 min in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Novel Multifunctional Polymers from Aromatic Diamines by Oxidative Polymerizations
Li, X.-G., Huang, M.-R., Duan, W., & Yang, Y.-L. (2002) · Chemical Reviews · doi:10.1021/cr010423z · Cited by 682
Electroconductive hydrogels: Synthesis, characterization and biomedical applications
Guiseppi-Elie, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.052 · Cited by 646
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
Metadata
- Authors
- Moussy, F., Harrison, D. J., O'Brien, D. W., & Rajotte, R. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-08-01
- Volume
- 65
- Issue
- 15
- Pages
- 2072-2077
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2003388886
- Cited by
- 158
- References
- 1
- FWCI
- 13.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating. https://app.cochat.ai/papers/10.1021/ac00063a023
- The paper
- Moussy, F., Harrison, D. J., O'Brien, D. W., & Rajotte, R. V. (1993). Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating. Analytical Chemistry. https://doi.org/10.1021/ac00063a023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.