The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Glucose-Sensing Electrode Coated with Polymer Complex Gel Containing Phenylboronic Acid
Abstract
We have prepared a copolymer containing both phenylboronic acid and tertiary amine moieties. The copolymer forms a stable complex with poly(vinyl alcohol) (PVA) since boronate moieties interact with PVA hydroxyl groups. The polymer-polymer complex changes its swelling degree with glucose concentration in Dulbecco's phosphate-buffered saline solution (PBS) at pH 7.4, due to the higher complex formation of boronic acid moieties with glucose hydroxyl groups over those in PVA. Glucose-responsive swelling changes of a membrane complex were then utilized to control glucose-responsive current changes with a membrane-coated platinum electrode. Glucose addition to PBS induces swelling of the cast gel membrane, leading to increased diffusion of ion species and thus increased measurable current changes. Since the addition of methyl α-d-glucoside has little influence on the current changes, the current change by the addition of glucose is indicative of the high selectivity of this system for glucose and its cis-hydroxyl groups in glucose. It is observed that current changes are proportional to glucose concentration in the range 0-300 mg/dL. This range corresponds well to physiological blood glucose levels. Current change rates determined from the slope of the time course immediately after glucose addition are also proportional to glucose concentration within this range, yielding even higher sensitivity to the change in glucose concentration. Reproducible signal output is also demonstrated by repetitive, stepwise glucose concentration changes. These results support the applicability of the platinum electrode coated with the gel membrane complex comprising a phenylboronic acid-containing polymer and PVA for a novel glucose-sensing device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Cited by
Synthesis and Applications of Boronic Acid-Containing Polymers: From Materials to Medicine
Brooks, W. L. A., & Sumerlin, B. S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00300 · Cited by 981
Kataoka, K., Miyazaki, H., Bunya, M., Okano, T., & Sakurai, Y. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982975d · Cited by 590
Self-citationStimuli-responsive hydrogel thin films
Tokarev, I., & Minko, S. (2009) · Soft Matter · doi:10.1039/b813827c · Cited by 579
Photonic Crystal Carbohydrate Sensors: Low Ionic Strength Sugar Sensing
Asher, S. A., Alexeev, V. L., Goponenko, A. V., Sharma, A. C., Lednev, I. K., Wilcox, C. S., & Finegold, D. N. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021037h · Cited by 488
Cho, S., Hwang, S. Y., Oh, D. X., & Park, J. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta02308j · Cited by 482
Metadata
- Authors
- Kikuchi, A., Suzuki, K., Okabayashi, O., Hoshino, H., Kataoka, K., Sakurai, Y., & Okano, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-03-01
- Volume
- 68
- Issue
- 5
- Pages
- 823-828
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2071856508
- Cited by
- 168
- References
- 1
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glucose-Sensing Electrode Coated with Polymer Complex Gel Containing Phenylboronic Acid. https://app.cochat.ai/papers/10.1021/ac950748d
- The paper
- Kikuchi, A., Suzuki, K., Okabayashi, O., Hoshino, H., Kataoka, K., Sakurai, Y., & Okano, T. (1996). Glucose-Sensing Electrode Coated with Polymer Complex Gel Containing Phenylboronic Acid. Analytical Chemistry. https://doi.org/10.1021/ac950748d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.