Recent advances in cortisol sensing technologies for point-of-care application
Abstract
Everyday lifestyle related issues are the main cause of psychological stress, which contributes to health disparities experienced by individuals. Prolonged exposure to stress leads to the activation of signaling pathways from the brain that leads to release of cortisol from the adrenal cortex. Various biomarkers have been affected by psychological stress, but cortisol "a steroid hormone" is known as a potential biomarker for its estimation. Cortisol can also be used as a target analyte marker to determine the effect of exposure such as organophosphates on central nervous system, which alters the endocrine system, leading to imbalance in cortisol secretion. Cortisol secretion of individuals depends on day-night cycle and field environment hence its detection at point-of-care (POC) is deemed essential to provide personalized healthcare. Chromatographic techniques have been traditionally used to detect cortisol. The issues relating to assay formation, system complexity, and multistep extraction/purification limits its application in the field. In order to overcome these issues and to make portable and effective miniaturized platform, various immunoassays sensing strategies are being explored. However, electrochemical immunosensing of cortisol is considered as a recent advancement towards POC application. Highly sensitive, label-free and selective cortisol immunosensor based on microelectrodes are being integrated with the microfluidic system for automated diurnal cortisol monitoring useful for personalized healthcare. Although the reported sensing devices for cortisol detection may have a great scope to improve portability, electronic designing, performance of the integrated sensor, data safety and lifetime for point-of-care applications, This review is an attempt to describe the various cortisol sensing platforms and their potential to be integrated into a wearable system for online and continuous monitoring of cortisol rhythm at POC as a function of one's environment.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Skin topography, skin temperature, and pH may interfere considerably with measurement results when sweat is sensed directly on the skin.
“In addition, since sweat is not sampled but sensed directly on the skin, the skin topography, skin temperature[ 10 ] and pH[ 11 ] may interfere considerably with the measurement results.”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [11]
Vents located on top of the storage chambers that are <300 μm in diameter prevent sweat evaporation and help preserve the molecular contents of the sweat in the stored fibers.
“The vents located on top of the storage chambers are <300 µm in diameter to prevent sweat evaporation (based on the Langmuir's free evaporation equation in vacuum[ 11 , 18 ] (see Section S4, Supporting Information) and help preserve the molecular contents of the sweat in the stored fibers.”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [11]
Cites
Stress and the brain: from adaptation to disease
de Kloet, E. R., Joëls, M., & Holsboer, F. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1683 · Cited by 4,621 · see citing works
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,690 · see citing works
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,518 · see citing works
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,458 · see citing works
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076 · see citing works
Russell, E., Koren, G., Rieder, M., & Van Uum, S. (2012) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2011.09.009 · Cited by 1,063 · see citing works
Shankaran, D. R., Gobi, K. V., & Miura, N. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.09.014 · Cited by 603 · see citing works
Kirschbaum, C., Tietze, A., Skoluda, N., & Dettenborn, L. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.08.024 · Cited by 584 · see citing works
Measurement of cortisol in human Hair as a biomarker of systemic exposure
Koren, G., Grace Walsh, R. N., Tokmakejian, S., & Uum, S. H. M. V. (2007) · Clinical and investigative medicine · doi:10.25011/cim.v30i5.2894 · Cited by 578 · see citing works
What is stress, and how does it affect reproduction?
Dobson, H., & Smith, R. F. (2000) · Animal Reproduction Science · doi:10.1016/s0378-4320(00)00080-4 · Cited by 549 · see citing works
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504 · see citing works
YEHUDA, R., HALLIGAN, S. L., & GROSSMAN, R. (2001) · Development and Psychopathology · doi:10.1017/s0954579401003170 · Cited by 490 · see citing works
Stress Hormone Regulation: Biological Role and Translation into Therapy
Holsboer, F., & Ising, M. (2010) · Annual Review of Psychology · doi:10.1146/annurev.psych.093008.100321 · Cited by 473 · see citing works
Measuring cortisol in human psychobiological studies
Levine, A., Zagoory‐Sharon, O., Feldman, R., Lewis, J. G., & Weller, A. (2006) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.08.025 · Cited by 472 · see citing works
Label-free screening of bio-molecular interactions
Cooper, M. A. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2111-y · Cited by 457 · see citing works
Point-of-care biosensor systems for cancer diagnostics/prognostics
Soper, S. A., Brown, K. C., Ellington, A. D., Frazier, B., Garcia‐Manero, G., Gau, V., Gutman, S. I., Hayes, D. F., Korte, B. J., Landers, J. L., et al. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.006 · Cited by 377 · see citing works
Delahanty, D. L., Raimonde, A. J., & Spoonster, E. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(00)00896-9 · Cited by 351 · see citing works
Detection of physiological concentrations of cortisol and cortisone in human hair
Raul, J.-S., Cirimele, V., Ludes, B., & Kintz, P. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.02.010 · Cited by 348 · see citing works
Microneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 344 · see citing works
A Radioimmunoassay for Cortisol in Plasma and Urine
Ruder, H. J., Guy, R. L., & Lipsett, M. B. (1972) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-35-2-219 · Cited by 330 · see citing works
An assessment of cortisol analysis in hair and its clinical applications
Gow, R., Thomson, S., Rieder, M., Van Uum, S., & Koren, G. (2010) · Forensic Science International · doi:10.1016/j.forsciint.2009.12.040 · Cited by 329 · see citing works
A review of experimental aspects of electrochemical immunosensors
Ricci, F., Adornetto, G., & Palleschi, G. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.06.033 · Cited by 328 · see citing works
Evaluation of a method to measure long term cortisol levels
Manenschijn, L., Koper, J. W., Lamberts, S. W. J., & van Rossum, E. F. C. (2011) · Steroids · doi:10.1016/j.steroids.2011.04.005 · Cited by 322 · see citing works
Microchip Electrophoretic Immunoassay for Serum Cortisol
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M. (1996) · Analytical Chemistry · doi:10.1021/ac9508311 · Cited by 315 · see citing works
Use of saliva for monitoring unbound free cortisol levels in serum
Teruhisa, U., Ryoji, H., Taisuke, I., Tatsuya, S., Fumihiro, M., & Tatsuo, S. (1981) · Clinica Chimica Acta · doi:10.1016/0009-8981(81)90353-3 · Cited by 314 · see citing works
Effect of childhood physical abuse on cortisol stress response
Carpenter, L. L., Shattuck, T. T., Tyrka, A. R., Geracioti, T. D., & Price, L. H. (2011) · Psychopharmacology · doi:10.1007/s00213-010-2007-4 · Cited by 307 · see citing works
Nicolson, N. A. (2008) · Sage eBooks · doi:10.4135/9781412976244.n3 · Cited by 286 · see citing works
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267 · see citing works
Rapid electrochemical detection on a mobile phone
Lillehoj, P. B., Huang, M.-C., Truong, N., & Ho, C. (2013) · Lab on a Chip · doi:10.1039/c3lc50306b · Cited by 259 · see citing works
The relationship between stress and hair cortisol in healthy pregnant women
Kalra, S., Einarson, A., Karaskov, T., Uum, S. H. M. V., & Koren, G. (2007) · Clinical and investigative medicine · doi:10.25011/cim.v30i2.986 · Cited by 238 · see citing works
Age of appearance of circadian rhythm in salivary cortisol values in infancy.
Price, D., Close, G. C., & Fielding, B. (1983) · Archives of Disease in Childhood · doi:10.1136/adc.58.6.454 · Cited by 236 · see citing works
A novel method using hair for determining hormonal levels in wildlife
Koren, L., Mokady, O., Karaskov, T., Klein, J., Koren, G., & Geffen, E. (2002) · Animal Behaviour · doi:10.1006/anbe.2001.1907 · Cited by 235 · see citing works
Development of electrochemical immunosensors towards point of care diagnostics
Wan, Y., Su, Y. L., Zhu, X., Liu, G., & Fan, C. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.045 · Cited by 232 · see citing works
Boumba, V. A., Ziavrou, K. S., & Vougiouklakis, T. (2006) · International Journal of Toxicology · doi:10.1080/10915810600683028 · Cited by 221 · see citing works
McRae‐Clark, A. L., Saladin, M. E., Brady, K. T., Upadhyaya, H. P., Back, S. E., & Timmerman, M. A. (2006) · Human Psychopharmacology Clinical and Experimental · doi:10.1002/hup.778 · Cited by 217 · see citing works
Cortisol assays and diagnostic laboratory procedures in human biological fluids
Gatti, R. D., Antonelli, G., Prearo, M., Spinella, P., Cappellin, E., & Palo, E. F. D. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.04.011 · Cited by 213 · see citing works
Wearable medical devices for tele-home healthcare
Hung, K., Zhang, Y. T., & Tai, B. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404503 · Cited by 211 · see citing works
CHANGES IN CORTISOL METABOLISM FOLLOWING RIFAMPICIN THERAPY
Om, E., GALLEY, J. M., Courtenay-Evans, R. J., Hunter, J. O., & Tait, A. D. (1974) · The Lancet · doi:10.1016/s0140-6736(74)91876-5 · Cited by 209 · see citing works
The Detection of Cortisol in Human Sweat
Russell, E., Koren, G., Rieder, M. J., & Uum, S. H. M. V. (2013) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31829daa0a · Cited by 195 · see citing works
Late-night salivary cortisol as a screening test for cushing's syndrome
Raff, H. (1998) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.83.8.2681 · Cited by 194 · see citing works
Cortisol in hair, body mass index and stress-related measures
Tobias Stalder, A., Steudte‐Schmiedgen, S., Alexander, N., Miller, R. E., Gao, W., Dettenborn, L., & Kirschbaum, C. (2012) · Biological Psychology · doi:10.1016/j.biopsycho.2012.03.010 · Cited by 182 · see citing works
Stevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179 · see citing works
Yehuda, R., Halligan, S. L., & Bierer, L. M. (2002) · Psychoneuroendocrinology · doi:10.1016/s0306-4530(01)00043-9 · Cited by 175 · see citing works
le Roux, C. W., Chapman, G. A., Kong, W. M., Dhillo, W. S., Jones, J., & Alaghband-Zadeh, J. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021532 · Cited by 146 · cited 2× · see citing works
“However, free cortisol is the only biologically active fraction (Le Roux et al., 2003) and is responsible for all cortisol-related activities in the body.”
BackgroundMethodBiomarkers of Psychological Stress in Health Disparities Research
Djurić, Z., Bird, C. E., Furumoto-Dawson, A., Rauscher, G. H., Ruffin, M. T., Stowe, R. P., Tucker, K. L., & Masi, C. M. (2008) · The Open Biomarkers Journal · doi:10.2174/1875318300801010007 · Cited by 145 · see citing works
Improving Healthcare Accessibility through Point-of-Care Technologies
Price, C. P., & Kricka, L. J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084707 · Cited by 142 · see citing works
Radioimmunoassay of Plasma Cortisol
Abraham, G. E., Buster, J. E., & Teller, R. C. (1972) · Analytical Letters · doi:10.1080/00032717208069558 · Cited by 140 · see citing works
VanBruggen, M., Hackney, A. C., McMurray, R. G., & Ondrak, K. S. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.396 · Cited by 138 · see citing works
Corbalán-Tutau, D., Madrid, J. A., Nicolás, F., & Garaulet, M. (2012) · Physiology & Behavior · doi:10.1016/j.physbeh.2012.06.005 · Cited by 134 · see citing works
Use of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
El-Laboudi, A. H., Oliver, N. S., Cass, A. E. G., & Johnston, D. G. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0188 · Cited by 133 · see citing works
Parallel Radioimmunoassay for Plasma Cortisol and 11-Deoxycortisol
Kao, M., Voina, S. J., Nichols, A., & Horton, R. (1975) · Clinical Chemistry · doi:10.1093/clinchem/21.11.1644 · Cited by 129 · see citing works
An LTCC-based microfluidic system for label-free, electrochemical detection of cortisol
Vasudev, A., Kaushik, A. K., Tomizawa, Y., Norena, N., & Bhansali, S. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.096 · Cited by 126 · see citing works
Self-citationArya, S. K., Dey, A., & Bhansali, S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.015 · Cited by 118 · see citing works
Self-citationLabel-free, chemiresistor immunosensor for stress biomarker cortisol in saliva
Tlili, C., Myung, N. V., Shetty, V., & Mulchandani, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.045 · Cited by 117 · see citing works
Arya, S. K., Chornokur, G., Venugopal, M., & Bhansali, S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.016 · Cited by 115 · see citing works
Self-citationPervanidou, P., Kolaitis, G., Charitaki, S., Lazaropoulou, C., Papassotiriou, I., Hindmarsh, P., Bakoula, C., Tsiantis, J., & Chrousos, G. P. (2007) · Biological Psychiatry · doi:10.1016/j.biopsych.2007.02.008 · Cited by 110 · see citing works
Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies
Chan, C. P.-Y., Mak, W. C., Cheung, K. Y., Sin, K. K., Yu, C., Rainer, T. H., & Renneberg, R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092641 · Cited by 107 · see citing works
A specific, non-chromatographic radioimmunoassay for human plasma cortisol
Dash, R. J., England, B. G., MIDGLEY, A. R., & NISWENDER, G. D. (1975) · Steroids · doi:10.1016/0039-128x(75)90057-4 · Cited by 106 · see citing works
Capillary Electrophoresis-Based Immunoassay for Cortisol in Serum
Schmalzing, D., Nashabeh, W., Yao, X.-W., Mhatre, R., Regnier, F. E., Afeyan, N. B., & Fuchs, M. (1995) · Analytical Chemistry · doi:10.1021/ac00099a019 · Cited by 104 · see citing works
Interfacial microfluidic transport on micropatterned superhydrophobic textile
Xing, S., Jiang, J., & Pan, T. (2013) · Lab on a Chip · doi:10.1039/c3lc41255e · Cited by 102 · see citing works
HPLC-FLU detection of cortisol distribution in human hair
Gao, W., Xie, Q., Jin, J., Qiao, T., Wang, H., Chen, L., Deng, H., & Lu, Z. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.01.014 · Cited by 101 · see citing works
Shimada, M., Takahashi, K., Ohkawa, T., Segawa, M., & Higurashi, M. (2008) · Hormone Research · doi:10.1159/000184628 · Cited by 101 · see citing works
A realtime and continuous assessment of cortisol in ISF using electrochemical impedance spectroscopy
Venugopal, M., Arya, S. K., Chornokur, G., & Bhansali, S. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.04.028 · Cited by 100 · see citing works
Self-citationDetermination of urinary free cortisol by HPLC
Turpeinen, U., Markkanen, H. M., Välimäki, M. J., & Stenman, U. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1386 · Cited by 99 · see citing works
An enzyme-linked immunosorbent assay (ELISA) for plasma cortisol
Lewis, J. G., & Elder, P. A. (1985) · Journal of Steroid Biochemistry · doi:10.1016/0022-4731(85)90222-5 · Cited by 97 · see citing works
Immunosensor with fluid control mechanism for salivary cortisol analysis
Yamaguchi, M., Matsuda, Y., Sasaki, S., SASAKI, M., Kadoma, Y., Imai, Y., Niwa, D., & Shetty, V. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.016 · Cited by 95 · see citing works
Automated Measurement of Salivary Cortisol
van Aken, M. O., Romijn, J. A., Miltenburg, J. A., & Lentjes, E. G. W. M. (2003) · Clinical Chemistry · doi:10.1373/49.8.1408 · Cited by 93 · see citing works
Episodic 24-Hour Cortisol Secretory Patterns in Patients Awaiting Elective Cardiac Surgery
Czeisler, C. A., Moore‐Ede, M. C., Regestein, Q. R., Kisch, E. S., Fang, V. S., & Ehrlich, E. N. (1976) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-42-2-273 · Cited by 91 · see citing works
Gómez-Sánchez, C. E., Milewich, L., & Holland, O. B. (1977) · PubMed · Cited by 83 · see citing works
Surface plasmon resonance immunosensor for cortisol and cortisone determination
Frasconi, M., Mazzarino, M., Botrè, F., & Mazzei, F. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2914-6 · Cited by 81 · see citing works
Antibody functionalized interdigitated μ-electrode (IDμE) based impedimetric cortisol biosensor
Arya, S. K., Chornokur, G., Venugopal, M., & Bhansali, S. (2010) · The Analyst · doi:10.1039/c0an00242a · Cited by 80 · see citing works
Self-citationMitchell, J. S., Lowe, T. E., & Ingram, J. R. (2008) · The Analyst · doi:10.1039/b817083p · Cited by 79 · see citing works
Venugopal, M., Feuvrel, K. E., Mongin, D., Bambot, S., Faupel, M., Panangadan, A., Talukder, A., & Pidva, R. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912544 · Cited by 76 · see citing works
Kumar, A., Aravamudhan, S., Gordic, M., Bhansali, S., & Mohapatra, S. S. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.09.035 · Cited by 75 · see citing works
Self-citationAn immunoelectrochemical sensor for salivary cortisol measurement
Sun, K., Ramgir, N. S., & Bhansali, S. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.03.018 · Cited by 66 · see citing works
Self-citationMeasurement of morning saliva cortisol in athletes
Lippi, G., Vita, F. D., Salvagno, G. L., Gelati, M., Montagnana, M., & Guidi, G. C. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.02.012 · Cited by 61 · see citing works
Microneedle-Based Automated Therapy for Diabetes Mellitus
Khanna, P., Strom, J. A., Malone, J. I., & Bhansali, S. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200621 · Cited by 61 · see citing works
Self-citationKaushik, A. K., Vasudev, A., Arya, S. K., & Bhansali, S. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.012 · Cited by 59 · see citing works
Self-citationA USB-based electrochemical biosensor prototype for point-of-care diagnosis
Loncaric, C., Tang, Y., Ho, C., Parameswaran, M. A., & Yu, H. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.061 · Cited by 58 · see citing works
QCM biosensor with ultra thin polymer film
Atashbar, M. Z., Bejcek, B. E., Vijh, A., & Singamaneni, S. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.047 · Cited by 56 · see citing works
Fiber-packed SPE tips based on electrospun fibers
Zhang, Y., Kang, X., Chen, L., Pan, C., Yao, Y., & Gu, Z. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2145-2 · Cited by 56 · see citing works
Belaya, Z. E., Iljin, A. V., Mel'nichenko, G. A., Rozhinskaya, L. Y., Dragunova, N. V., Dzeranova, L. K., Бутрова, С. А., Troshina, E. A., & Dedov, I. I. (2012) · Endocrine · doi:10.1007/s12020-012-9658-3 · Cited by 55 · see citing works
Disposable immunosensor for cortisol using functionalized magnetic particles
Moreno‐Guzmán, M., Eguílaz, M., Campuzano, S., González-Cortés, A., Yáñez‐Sedeño, P., & Pingarrón, J. M. (2010) · The Analyst · doi:10.1039/c0an00206b · Cited by 54 · see citing works
At home testing: optimizing management for the infertility physician
Brezina, P. R., Haberl, E. M., & Wallach, E. E. (2011) · Fertility and Sterility · doi:10.1016/j.fertnstert.2011.01.001 · Cited by 54 · see citing works
A fluorimetric assay for cortisol
Appel, D., Schmid, R. D., Drăgan, C.-A., Bureik, M., & Urlacher, V. B. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0022-9 · Cited by 51 · see citing works
Small, B. C., & Davis, K. B. (2002) · Journal of the World Aquaculture Society · doi:10.1111/j.1749-7345.2002.tb00493.x · Cited by 49 · see citing works
Thermostable Llama Single Domain Antibodies for Detection of Botulinum A Neurotoxin Complex
Goldman, E. R., Anderson, G. P., Conway, J. O., Sherwood, L. J., Fech, M., Vo, B. T., Liu, J. L., & Hayhurst, A. (2008) · Analytical Chemistry · doi:10.1021/ac8014774 · Cited by 49 · see citing works
A Piezoelectric Immunosensor for the Detection of Cortisol
Attili, B. S., & Suleiman, A. A. (1995) · Analytical Letters · doi:10.1080/00032719508000035 · Cited by 48 · see citing works
Carrozza, C., Corsello, S. M., Paragliola, R. M., Ingraudo, F., Palumbo, S., Locantore, P., Sferrazza, A., Pontecorvi, A., & Zuppi, C. (2010) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2010.010020 · Cited by 47 · see citing works
Cortisol, Cushing's Syndrome, and a Shrinking Brain--New Evidence for Reversibility
McEwen, B. S. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.5.9999 · Cited by 47 · see citing works
Wearable Devices in Healthcare
Glaros, C., & Fotiadis, D. I. (2005) · Studies in fuzziness and soft computing · doi:10.1007/11311966_8 · Cited by 47 · see citing works
Improved liquid-chromatographic method for determination of serum cortisol.
Kabra, P. M., Tsai, L. L., & Marton, L. J. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.7.1293 · Cited by 45 · see citing works
Løvås, K., Thorsen, T. E., & Husebye, E. S. (2006) · Journal of Endocrinological Investigation · doi:10.1007/bf03344183 · Cited by 43 · see citing works
Chen, L., Kang, X., Sun, J., Deng, J., Gu, Z., & Lu, Z. (2010) · Journal of Separation Science · doi:10.1002/jssc.201000071 · Cited by 41 · see citing works
Shi, H., Xu, X., Ding, Y., Liu, S., Li, L., & Kang, W. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2009.01.014 · Cited by 39 · see citing works
Capillary electrophoretic enzyme immunoassay with electrochemical detection for thyroxine
He, Z., & Jin, W. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00508-0 · Cited by 38 · see citing works
Yaneva, M., Кirilov, G., & Zacharieva, S. (2009) · Open Medicine · doi:10.2478/s11536-009-0004-y · Cited by 38 · see citing works
Fluorescence polarization immunoassay for cortisol
Kobayashi, Y., Amitani, K., Watanabe, F., & Miyai, K. (1979) · Clinica Chimica Acta · doi:10.1016/0009-8981(79)90119-0 · Cited by 37 · see citing works
Yang, X., Chang, W.-B., & Ci, Y. (1994) · Analytical Chemistry · doi:10.1021/ac00087a026 · Cited by 31 · see citing works
Intelligent Paradigms for Healthcare Enterprises
Silverman, B. G., Jain, L., Ichalkaranje, A., & Jain, A. (2005) · Studies in fuzziness and soft computing · doi:10.1007/b99809 · Cited by 31 · see citing works
Arya, S. K., Chornokur, G., Venugopal, M., & Bhansali, S. (2010) · Procedia Engineering · doi:10.1016/j.proeng.2010.09.230 · Cited by 30 · see citing works
Self-citationA Bioluminescent Probe for Salivary Cortisol
Kim, S. B., Takenaka, Y., & Torimura, M. (2011) · Bioconjugate Chemistry · doi:10.1021/bc200220k · Cited by 30 · see citing works
Electrospun phospholipid polymer substrate for enhanced performance in immunoassay system
Chantasirichot, S., & Ishihara, K. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.05.029 · Cited by 29 · see citing works
Detection of FITC-cortisol via Modulated Supraparticle Lighthouses
Petkus, M. M., McLauchlin, M. L., Vuppu, A. K., Rios, L., Garcia, A. A., & Hayes, M. A. (2006) · Analytical Chemistry · doi:10.1021/ac0512204 · Cited by 25 · see citing works
Capillary electrophoretic enzyme immunoassay with electrochemical detection for cortisol
Jia, M., He, Z., & Jin, W. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00701-x · Cited by 24 · see citing works
Differential Measurement of Cortisol and Cortisone in Human Saliva by HPLC with Uv Detection
Wade, S. E., & Haegele, A. D. (1991) · Journal of Liquid Chromatography · doi:10.1080/01483919108049655 · Cited by 22 · see citing works
High-performance thin-layer chromatographic determination of fluorescence-labelled cortisol
Funk, W., Kerler, R., Boll, E., & Dammann, V. (1981) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)88089-9 · Cited by 21 · see citing works
Klopfenstein, B. J., Purnell, J. Q., Brandon, D. D., Isabelle, L. M., & DeBarber, A. E. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.12.008 · Cited by 19 · see citing works
Point-of-use measurement of salivary cortisol levels
Yamaguchi, M., Yoshikawa, S., Tahara, Y., Niwa, D., Imai, Y., & Shetty, V. (2009) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2009.5398143 · Cited by 18 · see citing works
New, advantageous approach to the direct radioimmunoassay of cortisol.
Tilden, R. L. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.2.211 · Cited by 13 · see citing works
Van, C. E., Wierckx, K., Fiers, T., Segers, H., Vandersypt, E., & Kaufman, J. (2011) · 13th European Congress of Endocrinology · Cited by 9 · see citing works
Urinary cortisol metabolites in corticotroph and adrenal tumours
Brossaud, J., Ducint, D., Gatta, B., Molimard, M., Tabarin, A., & Corcuff, J. (2012) · 15th International & 14th European Congress of Endocrinology · Cited by 7 · see citing works
Sweat patch cortisol - a new screen for Cushing's syndrome
Prunty, H., Andrews, K. M., Reddy-Kolanu, G., Quinlan, P., & Wood, P. (2004) · Cited by 4 · see citing works
Howell, J. M., Luider, J. M., Wong, H. H., Perizzolo, M., Demetrick, D. J., Auer, I. A., & Mansoor, A. (2007) · Clinical and investigative medicine · doi:10.25011/cim.v30i4.2856 · Cited by 4 · see citing works
Flagged first, then by citations
1 of the 115 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603 · see citing works
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537 · see citing works
Ramesh, M., Janani, R., Deepa, C., & Rajeshkumar, L. (2022) · Biosensors · doi:10.3390/bios13010040 · Cited by 480 · see citing works
Jain, S., Nehra, M., Kumar, R., Dilbaghi, N., Hu, Y., Kumar, S., Kaushik, A. K., & Li, C.-Z. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113074 · Cited by 370 · see citing works
Self-citationA Wearable Cellulose Acetate-Coated Mouthguard Biosensor for In Vivo Salivary Glucose Measurement
Arakawa, T., Tomoto, K., Nitta, H., Toma, K., Takeuchi, S., Sekita, T., Minakuchi, S., & Mitsubayashi, K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01201 · Cited by 320 · see citing works
Smart, soft contact lens for wireless immunosensing of cortisol
Ku, M., Kim, J., Won, J., Kang, W., Park, Y., Park, J., Lee, J., Cheon, J., Lee, H. H., & Park, J. (2020) · Science Advances · doi:10.1126/sciadv.abb2891 · Cited by 274 · see citing works
Aptamer-based lateral flow assay for point of care cortisol detection in sweat
Dalirirad, S., & Steckl, A. J. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.161 · Cited by 260 · see citing works
Zhang, Y., Guo, H., Kim, S. B., Wu, Y., Ostojich, D., Park, S. H., Wang, X. S., Weng, Z., Li, R., Bandodkar, A. J., et al. (2019) · Lab on a Chip · doi:10.1039/c9lc00103d · Cited by 249 · see citing works
Recent advances and perspectives in sweat based wearable electrochemical sensors
Mohan, A. M. V., Rajendran, V., Mishra, R. K., & Mathiyarasu, J. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116024 · Cited by 234 · see citing works
Nano-enabled biosensing systems for intelligent healthcare: towards COVID-19 management
Mujawar, M. A., Gohel, H., Bhardwaj, S. K., Srinivasan, S. S., Hickman, N., & Kaushik, A. K. (2020) · Materials Today Chemistry · doi:10.1016/j.mtchem.2020.100306 · Cited by 229 · see citing works
Self-citationKaushik, A. K., Dhau, J. S., Gohel, H., Mishra, Y. K., Kateb, B., Kim, N., & Goswami, D. Y. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01004 · Cited by 226 · see citing works
Self-citationCorrie, S. R., Coffey, J. W., Islam, J., Markey, K. A., & Kendall, M. A. F. (2015) · The Analyst · doi:10.1039/c5an00464k · Cited by 220 · see citing works
Flexible Substrate-Based Devices for Point-of-Care Diagnostics
Wang, S., Chinnasamy, T., Lifson, M. A., İnci, F., & Demirci, U. (2016) · Trends in biotechnology · doi:10.1016/j.tibtech.2016.05.009 · Cited by 210 · see citing works
Sanghavi, B. J., Moore, J. A., Chávez, J. L., Hagen, J. A., Kelley‐Loughnane, N., Chou, C., & Swami, N. S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.044 · Cited by 188 · see citing works
Nanomolar Binding of Steroids to Cucurbit[n]urils: Selectivity and Applications
Lazar, A. I., Biedermann, F., Mustafina, K. R., Assaf, K. I., Hennig, A., & Nau, W. M. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b07655 · Cited by 186 · see citing works
Chemical analysis in saliva and the search for salivary biomarkers – a tutorial review
Ngamchuea, K., Chaisiwamongkhol, K., Batchelor‐McAuley, C., & Compton, R. G. (2017) · The Analyst · doi:10.1039/c7an01571b · Cited by 172 · see citing works
Nano-biosensors to detect beta-amyloid for Alzheimer's disease management
Kaushik, A. K., Jayant, R. D., Tiwari, S., Vashist, A., & Nair, M. G. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.065 · Cited by 167 · see citing works
Self-citationA low-cost miniaturized potentiostat for point-of-care diagnosis
Cruz, A. F. D., Norena, N., Kaushik, A. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.053 · Cited by 164 · see citing works
Self-citationApplication of 2D Non-Graphene Materials and 2D Oxide Nanostructures for Biosensing Technology
Shavanova, K. E., Bakakina, Y. S., Burkova, I., Shtepliuk, I., Viter, R., Úbelis, A., Beni, V., Starodub, N. F., Yakimova, R., & Khranovskyy, V. (2016) · Sensors · doi:10.3390/s16020223 · Cited by 164 · see citing works
Carbon fiber based electrochemical sensor for sweat cortisol measurement
Sekar, M. K., Pandiaraj, M., Bhansali, S., Ponpandian, N., & Viswanathan, C. (2019) · Scientific Reports · doi:10.1038/s41598-018-37243-w · Cited by 164 · see citing works
Self-citationExtended gate field-effect-transistor for sensing cortisol stress hormone
Sheibani, S., Capua, L., Kamaei, S., Akbari, S. S. A., Zhang, J., Guerin, H., & Ionescu, A. M. (2021) · Communications Materials · doi:10.1038/s43246-020-00114-x · Cited by 158 · see citing works
Wang, K., Yap, L. W., Gong, S. P., Wang, R., Wang, S. J., & Cheng, W. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008347 · Cited by 157 · see citing works
Vabbina, P. K., Kaushik, A. K., Pokhrel, N., Bhansali, S., & Pala, N. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.026 · Cited by 155 · see citing works
Self-citationLee, H.-B., Meeseepong, M., Trung, T. Q., Kim, B.-Y., & Lee, N.-E. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112133 · Cited by 153 · see citing works
Aptamer-Based Lateral Flow Biosensor for Rapid Detection of Salivary Cortisol
Dalirirad, S., Han, D., & Steckl, A. J. (2020) · ACS Omega · doi:10.1021/acsomega.0c03223 · Cited by 153 · see citing works
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
Seo, H., Chung, W. G., Kwon, Y. W., Kim, S., Hong, Y., Park, W., Kim, E., Lee, J., Lee, S., Kim, M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00290 · Cited by 152 · see citing works
Cheng, C., Li, X., Xu, G., Lu, Y., Low, S. S., Liu, G., Zhu, L., Li, C., & Liu, Q. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112782 · Cited by 151 · see citing works
Current Trends of Nanobiosensors for Point-of-Care Diagnostics
Noah, N. M., & Ndangili, P. M. (2019) · Journal of Analytical Methods in Chemistry · doi:10.1155/2019/2179718 · Cited by 146 · see citing works
Towards detection and diagnosis of Ebola virus disease at point-of-care
Kaushik, A. K., Tiwari, S., Jayant, R. D., Marty, A. M., & Nair, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.040 · Cited by 142 · see citing works
Self-citationFlexible nanoporous tunable electrical double layer biosensors for sweat diagnostics
Munje, R. D., Muthukumar, S., Panneer Selvam, A., & Prasad, S. (2015) · Scientific Reports · doi:10.1038/srep14586 · Cited by 138 · see citing works
Microfluidic paper-based wearable electrochemical biosensor for reliable cortisol detection in sweat
Fiore, L., Mazzaracchio, V., Serani, A., Fabiani, G., Fabiani, L., Volpe, G., Moscone, D., Bianco, G. M., Occhiuzzi, C., Marrocco, G., et al. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.133258 · Cited by 136 · see citing works
High-Affinity Nucleic-Acid-Based Receptors for Steroids
Yang, K.-A., Chun, H.-S., Zhang, Y., Pecic, S., Nakatsuka, N., Andrews, A. M., Worgall, T. S., & Stojanović, M. N. (2017) · ACS Chemical Biology · doi:10.1021/acschembio.7b00634 · Cited by 130 · see citing works
He, H., Fu, Y., Zhao, T., Gao, X.-C., Xing, L., Zhang, Y., & Xue, X. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.07.033 · Cited by 129 · see citing works
Sweat and saliva cortisol response to stress and nutrition factors
Pearlmutter, P., Derose, G., Samson, C., Linehan, N., Cen, Y., Begdache, L., Won, D., & Koh, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-75871-3 · Cited by 128 · see citing works
Wearable and Implantable Cortisol‐Sensing Electronics for Stress Monitoring
Ok, J., Park, S., Jung, Y. H., & Kim, T. (2023) · Advanced Materials · doi:10.1002/adma.202211595 · Cited by 120 · see citing works
Review—Towards Wearable Sensor Platforms for the Electrochemical Detection of Cortisol
Sekar, M. K., Sriramprabha, R., Sekhar, P. K., Bhansali, S., Ponpandian, N., Manickam, P., & Viswanathan, C. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab7e24 · Cited by 118 · see citing works
Self-citationElectrochemical sensors for cortisol detections: Almost there
Zea, M., Bellagambi, F. G., Halima, H. B., Zine, N., Jaffrezic-Renault, N. J., Villa, R., Gabriel, G., & Errachid, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116058 · Cited by 118 · see citing works
Jia, M., Chew, W. M., Feinstein, Y., Skeath, P., & Sternberg, E. M. (2016) · The Analyst · doi:10.1039/c5an02387d · Cited by 113 · see citing works
Xiao, W., Huang, C., Xu, F., Yan, J., Bian, H., Fu, Q., Xie, K., Wang, L., & Tang, Y. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.03.110 · Cited by 111 · see citing works
System Architectures in Wearable Electrochemical Sensors
Steinberg, M. D., Kassal, P., & Steinberg, I. M. (2016) · Electroanalysis · doi:10.1002/elan.201600094 · Cited by 107 · see citing works
Nardo, F. D., Cavalera, S., Baggiani, C., Giovannoli, C., & Anfossi, L. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b11559 · Cited by 107 · see citing works
Ganguly, A., Lin, K., Muthukumar, S., & Prasad, S. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01754 · Cited by 106 · see citing works
Recent advances in electrochemiluminescence devices for point-of-care testing
Gao, W., Saqib, M., Qi, L., Zhang, W. Y., & Xu, G. (2017) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2017.03.003 · Cited by 103 · see citing works
Biomolecule sensors based on organic electrochemical transistors
Lu, Z., Xu, K., Xiao, K. J., Xu, Q., Wang, L., Li, P., Zhou, J., Zhao, D., Bai, L., Cheng, Y., et al. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00383-x · Cited by 100 · see citing works
Jo, S., Lee, W., Park, J., Kim, W., Kim, W., Lee, G., Lee, H., Hong, J., & Park, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127424 · Cited by 98 · see citing works
Printed microfluidic sweat sensing platform for cortisol and glucose detection
Naik, A. R., Zhou, Y., Dey, A. A., Arellano, D. L. G., Okoroanyanwu, U., Secor, E. B., Hersam, M. C., Morse, J. D., Rothstein, J. P., Carter, K. R., et al. (2021) · Lab on a Chip · doi:10.1039/d1lc00633a · Cited by 97 · see citing works
A Portable 3D Microfluidic Origami Biosensor for Cortisol Detection in Human Sweat
Weng, X., Fu, Z., Zhang, C., Jiang, W. R., & Jiang, H. M. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04508 · Cited by 96 · see citing works
Sensitive electrochemical detection of Salmonella with chitosan–gold nanoparticles composite film
Xiang, C., Li, R., Adhikari, B., She, Z., Li, Y., & Kraatz, H. (2015) · Talanta · doi:10.1016/j.talanta.2015.03.033 · Cited by 94 · see citing works
Usha, S. P., Shrivastav, A. M., & Gupta, B. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.040 · Cited by 94 · see citing works
Current methods for stress marker detection in saliva
Giacomello, G., Scholten, A., & Parr, M. K. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113604 · Cited by 91 · see citing works
Inkjet Printing: A Viable Technology for Biosensor Fabrication
Hussain, A., Abbas, N., & Ali, A. (2022) · Chemosensors · doi:10.3390/chemosensors10030103 · Cited by 91 · see citing works
Comparison of Colorimetric Analyses to Determine Cortisol in Human Sweat
Tu, E., Pearlmutter, P., Tiangco, M., Derose, G., Begdache, L., & Koh, A. (2020) · ACS Omega · doi:10.1021/acsomega.0c00498 · Cited by 90 · see citing works
Luppa, P. B., Bietenbeck, A., Beaudoin, C. A., & Giannetti, A. E. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.01.003 · Cited by 89 · see citing works
Özgöçer, T., Yıldız, S., & Uçar, C. (2016) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2016.1230130 · Cited by 88 · see citing works
Electrochemical Biosensors for Early Stage Zika Diagnostics
Kaushik, A. K., Tiwari, S., Jayant, R. D., Vashist, A., Nikkhah-Moshaie, R., El‐Hage, N., & Nair, M. G. (2016) · Trends in biotechnology · doi:10.1016/j.tibtech.2016.10.001 · Cited by 88 · see citing works
Self-citationInjectable Biomedical Devices for Sensing and Stimulating Internal Body Organs
Jung, Y. H., Kim, J. U., Lee, J. S., Shin, J. H., Jung, W., Ok, J., & Kim, T. (2020) · Advanced Materials · doi:10.1002/adma.201907478 · Cited by 88 · see citing works
Cortisol detection methods for stress monitoring in connected health
Iqbal, T., Elahi, A., Wijns, W. C., & Shahzad, A. (2023) · Health Sciences Review · doi:10.1016/j.hsr.2023.100079 · Cited by 87 · see citing works
Miniaturized high-performance liquid chromatography instrumentation
Lynch, K. B., Chen, A., & Liu, S. (2017) · Talanta · doi:10.1016/j.talanta.2017.09.016 · Cited by 85 · see citing works
Karuppaiah, G., Lee, M., Bhansali, S., & Manickam, P. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115600 · Cited by 82 · see citing works
Self-citationSchlotz, W. (2018) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2018.11.038 · Cited by 81 · see citing works
Jang, H.-J., Lee, T., Song, J., Russell, L., Li, H., Dailey, J., Searson, P. C., & Katz, H. E. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18855 · Cited by 80 · see citing works
Lee, M. A., Wang, S., Jin, X., Bakh, N. A., Nguyen, F. T., Dong, J. I., Silmore, K. S., Gong, X., Pham, C., Jones, K. K., et al. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000429 · Cited by 80 · see citing works
Electrochemical Sensing of Cortisol: A Recent Update
Singh, A., Kaushik, A. K., Kumar, R., Nair, M. G., & Bhansali, S. (2014) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-014-0894-2 · Cited by 80 · see citing works
Self-citationSingh, N. K., Chung, S., Sveiven, M., & Hall, D. A. (2021) · ACS Omega · doi:10.1021/acsomega.1c03552 · Cited by 78 · see citing works
Jayant, R. D., Yndart, A., Sagar, V., Bhansali, S., Nair, M. G., Kaushik, A. K., & Atluri, V. S. R. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s75514 · Cited by 77 · see citing works
Self-citationMitigation of stress: new treatment alternatives
Subhani, A. R., Kamel, N., Saad, M. N. M., Nandagopal, D., Kang, K., & Malik, A. S. (2017) · Cognitive Neurodynamics · doi:10.1007/s11571-017-9460-2 · Cited by 73 · see citing works
Prakash, J., Parveen, A., Mishra, Y. K., & Kaushik, A. K. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112562 · Cited by 73 · see citing works
Self-citationTian, G., Zhou, Z., Li, M., Li, X., Xu, T., & Zhang, X. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c02392 · Cited by 73 · see citing works
Disposable electrochemical immunosensor for cortisol determination in human saliva
Kämäräinen, S., Mäki, M., Tolonen, T., Palleschi, G., Virtanen, V., Micheli, L., & Sesay, A. M. (2018) · Talanta · doi:10.1016/j.talanta.2018.05.039 · Cited by 72 · see citing works
Unobtrusive and Multimodal Wearable Sensing to Quantify Anxiety
Zheng, Y., Wong, T. C. H., Leung, B. H. K., & Poon, C. C. Y. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2539383 · Cited by 71 · see citing works
Point of Care Sensing Devices: Better Care for Everyone
Kaushik, A. K., & Mujawar, M. A. (2018) · Sensors · doi:10.3390/s18124303 · Cited by 69 · see citing works
Self-citationNeužil, P., Campos, C. D. M., Wong, C. C., Soon, J. B. W., Reboud, J., & Manz, A. (2014) · Lab on a Chip · doi:10.1039/c4lc00310a · Cited by 68 · see citing works
Salivary Cortisol Determination on Smartphone-Based Differential Pulse Voltammetry System
Liu, J., Xu, N., Men, H., Li, S., Lu, Y., Low, S. S., Li, X., Zhu, L., Cheng, C., Xu, G., et al. (2020) · Sensors · doi:10.3390/s20051422 · Cited by 68 · see citing works
Kim, K. S., Ryeol, L. S., Kim, S., Lee, J. Y., Chung, C., Choe, W., & Yoo, P. J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.135 · Cited by 66 · see citing works
Yadav, A. K., Verma, D., Kumar, A., Kumar, P., & Solanki, P. R. (2021) · Materials Today Chemistry · doi:10.1016/j.mtchem.2021.100443 · Cited by 64 · see citing works
Chronic and acute stress monitoring by electrophysiological signals from adrenal gland
Sunwoo, S. H., Lee, J. S., Bae, S., Shin, Y. J., Kim, C. S., Joo, S. Y., Choi, H. S., Suh, M., Kim, S. W., Choi, Y. J., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1806392115 · Cited by 64 · see citing works
Çay, M. (2017) · Northern Clinics of Istanbul · doi:10.14744/nci.2017.42103 · Cited by 63 · see citing works
SERS-based immunoassay for monitoring cortisol-related disorders
Villa, J. E. L., Garcı́a, I., de Aberasturi, D. J., Pavlov, V. V., Sotomayor, M. D. P. T., & Liz‐Marzán, L. M. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112418 · Cited by 63 · see citing works
Cortisol Immunosensors: A Literature Review
Karachaliou, C., Koukouvinos, G., Goustouridis, D., Raptis, I., Kakabakos, S. E., Petrou, P. S., & Livaniou, E. (2023) · Biosensors · doi:10.3390/bios13020285 · Cited by 63 · see citing works
Electrochemical Immunosensing of Saliva Cortisol
Pasha, S. K., Kaushik, A. K., Vasudev, A., Snipes, S. A., & Bhansali, S. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.017402jes · Cited by 63 · see citing works
Self-citationKhan, M. S., Dighe, K., Wang, Z., Srivastava, I., Schwartz‐Duval, A. S., Misra, S. K., & Pan, D. (2018) · The Analyst · doi:10.1039/c8an02085j · Cited by 63 · see citing works
Singh, A., Ahmed, A., Sharma, A., & Arya, S. K. (2022) · Biosensors · doi:10.3390/bios12100910 · Cited by 62 · see citing works
Self-citationPruna, R., Palacio, F., Baraket, A., Zine, N., Streklas, A., Bausells, J., Errachid, A., & López, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.049 · Cited by 62 · see citing works
Grand Challenges in Bio-Nanotechnology to Manage the COVID-19 Pandemic
Paliwal, P., Sargolzaei, S., Bhardwaj, S. K., Bhardwaj, V., Dixit, C. K., & Kaushik, A. K. (2020) · Frontiers in Nanotechnology · doi:10.3389/fnano.2020.571284 · Cited by 61 · see citing works
Self-citationChen, Y., Fu, Q., Li, D., Xie, J., Ke, D., Song, Q., Tang, Y., & Wang, H. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0605-2 · Cited by 61 · see citing works
Portable and wearable real-time stress monitoring: A critical review
Parlak, O. (2021) · Sensors and Actuators Reports · doi:10.1016/j.snr.2021.100036 · Cited by 60 · see citing works
Shirtcliff, E. A., Buck, R. L., Laughlin, M. J., Hart, T., Cole, C. R., & Slowey, P. D. (2015) · Clinical Therapeutics · doi:10.1016/j.clinthera.2015.02.014 · Cited by 58 · see citing works
Pandit, P., Crewther, B. T., Cook, C. J., Punyadeera, C., & Pandey, A. K. (2024) · Materials Advances · doi:10.1039/d3ma00937h · Cited by 57 · see citing works
Pusomjit, P., Teengam, P., Thepsuparungsikul, N., Sanongkiet, S., & Chailapakul, O. (2021) · Microchimica Acta · doi:10.1007/s00604-020-04692-y · Cited by 56 · see citing works
A Wearable Molecularly Imprinted Electrochemical Sensor for Cortisol Stable Monitoring in Sweat
Chen, Y., He, Z., Wu, Y., Bai, X., Li, Y., Yang, W., Liu, Y., & Li, R. (2025) · Biosensors · doi:10.3390/bios15030194 · Cited by 56 · see citing works
Pandey, A. K., Sharma, A. K., & Marques, C. (2020) · Materials · doi:10.3390/ma13071623 · Cited by 56 · see citing works
Shajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55 · see citing works
Balakrishnan, S. R., Hashim, U., Gopinath, S. C. B., POOPALAN, P., Ramayya, H. R., Omar, M. I., Haarindraprasad, R., & Perumal, V. (2015) · PLoS ONE · doi:10.1371/journal.pone.0137891 · Cited by 55 · see citing works
Hu, X., Wei, T., Wang, J., Liu, Z.-E., Li, X., Zhang, B., Li, Z., Li, L., & Yuan, Q. (2014) · Analytical Chemistry · doi:10.1021/ac5032308 · Cited by 55 · see citing works
Microfluidic immunosensor for rapid and highly-sensitive salivary cortisol quantification
Pinto, V. C., Sousa, P. J., Catarino, S. O., Correia‐Neves, M., & Minas, G. M. H. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.067 · Cited by 55 · see citing works
Rapid micromotor-based naked-eye immunoassay
de Ávila, B. E., Zhao, M., Campuzano, S., Ricci, F., Pingarrón, J. M., Mascini, M., & Wang, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.02.068 · Cited by 54 · see citing works
Manickam, P., Fernandez, T. F., Umasankar, Y., Muneeswaran, G., Arizaleta, F., Urizar, G. G., & Bhansali, S. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.133 · Cited by 54 · see citing works
Self-citationHalicka, K., Meloni, F., Czok, M. J., Spychalska, K., Baluta, S., Malecha, K., Pilo, M. I., & Cabaj, J. (2022) · ACS Omega · doi:10.1021/acsomega.2c04134 · Cited by 53 · see citing works
Gevaerd, A., Watanabe, E. Y., Belli, C., Junior, L. H. M., & Bergamini, M. F. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.129532 · Cited by 53 · see citing works
Cardiac troponin biosensors: where are we now?
Upasham, S., Tanak, A. S., & Prasad, S. (2018) · Advanced Health Care Technologies · doi:10.2147/ahct.s138543 · Cited by 52 · see citing works
- Authors
- Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S.
- Affiliations
- Florida International University (US)
- Agency for Science, Technology and Research (SG)
- Corresponding author
- Kaushik, Ajeet
- Bhansali, Shekhar
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 53
- Pages
- 499-512
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2013008702
- Cited by
- 316
- References
- 115
- Citations by year
- 2026: 13 · 2025: 23 · 2024: 30 · 2023: 31 · 2022: 35 · 2021: 33 · 2020: 36 · 2019: 21 · 2018: 24 · 2017: 18 · 2016: 31 · 2015: 12 · 2014: 8 · 2013: 1
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Forensic Sciences Foundation
- National Institute of Mental Health (R44MH085474)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- cortisol detection, point-of-care testing, electrochemical immunosensor, microelectrodes, microfluidics, wearable sensors, diurnal cortisol rhythm, organophosphate exposure, personalized healthcare, label-free detection
- MeSH terms
- Humans, Hydrocortisone, Immunoassay, Biosensing Techniques, Point-of-Care Systems, Microfluidics, Precision Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review