Analytical Properties and Sensor Size Effects of a Micrometer-Sized Optical Fiber Glucose Biosensor
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A micrometer-sized fiber-optic fluorescence biosensor for glucose has been fabricated. The sensor is 100 times smaller than existing glucose optodes. It is based on the enzymatic reaction of glucose oxidase that catalyzes the oxidation of glucose to gluconic acid and hydrogen peroxide while consuming oxygen. Tris(1,10-phenanthroline)ruthenium chloride, an oxygen indicator, is used as a transducer. The ruthenium complex and glucose oxidase are incorporated into acrylamide polymer that is attached covalently to a silanized optical fiber tip surface by photocontrolled polymerization. A study of the dependence of the fluorescence intensity on sensor size shows that, under normal operating conditions, the signal decreases with the sensor diameter rather than its volume. Also, the response of micrometer-sized sensors is improved by about 20% compared to that of larger fiber-optic glucose sensors. Due to its small size and the lack of membrane support, the response time of the sensor is only 2 s. An absolute detection limit of around 1 x 10(-15) mol is achieved. The new glucose sensor is at least 25 times faster and its absolute sensitivity 5-6 orders of magnitude higher than that of current glucose optodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Cited by
Borisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Optical methods for sensing glucose
Steiner, M.-S., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 497
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 371
Recent Development in Optical Fiber Biosensors
Bosch, M. E., Sánchez, A. J. R., Rojas, F. S., & Ojeda, C. B. (2007) · Sensors · doi:10.3390/s7060797 · Cited by 287
Metadata
- Authors
- Rosenzweig, Z., & Kopelman, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 8
- Pages
- 1408-1413
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2079957166
- Cited by
- 151
- References
- 2
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytical Properties and Sensor Size Effects of a Micrometer-Sized Optical Fiber Glucose Biosensor. https://app.cochat.ai/papers/10.1021/ac950864g
- The paper
- Rosenzweig, Z., & Kopelman, R. (1996). Analytical Properties and Sensor Size Effects of a Micrometer-Sized Optical Fiber Glucose Biosensor. Analytical Chemistry. https://doi.org/10.1021/ac950864g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.