Design of a Stable Charge Transfer Complex Electrode for a Third-Generation Amperometric Glucose Sensor
The DOI matches its Crossref record.
Abstract
A novel approach to prepare a stable charge transfer complex (CTC) electrode for the direct oxidation of flavoproteins and the fabrication of a third generation amperometric biosensor (Koopal, C.G.J.; Feiters, M.C.; Nolte, R.J.M. Bioelectrochem. Bioenerg. 1992, 29, 159-175) system is described. Tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ), an organic CTC, is grown at the surface of a shapable electroconductive (SEC) film (a polyanion-doped polypyrrole film) in such a way that it makes a tree-shaped crystal structure standing vertically on the surface. Glucose oxidase (GOx) is adsorbed and cross-linked with glutaraldehyde to fix at the surface of the CTC structure. The space between crystals is filled with cross-linked gelatin to ensure the stability of the treelike crystal structure as well as the stability of the enzyme. Because of the close proximity and the favorable orientation of the enzyme at the CTC surface, the enzyme is directly oxidized at the crystal surface, which leads to a glucose sensor with remarkably improved performance. It works at a potential from 0.0 to 0.25 V (vs Ag/AgCl). The maximum current density at 0.25 V reaches 1.8 mA/cm2, with an extended linear range. The oxygen in the normal buffer solution has little effect on the sensor output. The current caused by interference contained in the physiological fluids is negligible. The working life as well as the shelf life of the sensor is substantially prolonged. The sensor was continuously used in a flow injection system with a continuous polarization at 0.1 V, and the samples (usually 10 mM glucose) were injected at 30 min intervals. After 100 days of continuous use, the current output dropped to 40% of the initial level. No change in the output of the sensor was observed over a year when the sensor was stored dry in a freezer. The electrochemical rate constants and the effective Michaelis constant of the system are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene
Zhu, Z., Garcia-Gancedo, L., Flewitt, A. J., Xie, H., Moussy, F., & Milne, W. I. (2012) · Sensors · doi:10.3390/s120505996 · Cited by 549
Recent developments in faradaic bioelectrochemistry
Armstrong, F. A., & Wilson, G. S. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00342-x · Cited by 446
Enzyme‐catalyzed direct electron transfer: Fundamentals and analytical applications
Ghindilis, A. L., Atanasov, P., & Wilkins, E. (1997) · Electroanalysis · doi:10.1002/elan.1140090902 · Cited by 440
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation
Ward, W. K., Jansen, L. B., Anderson, E., Reach, G., Klein, J.-C., & Wilson, G. S. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00268-8 · Cited by 81
Metadata
- Authors
- Khan, G. F., Ohwa, M., & Wernet, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-09-01
- Volume
- 68
- Issue
- 17
- Pages
- 2939-2945
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2035096547
- Cited by
- 98
- References
- 0
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.