Standardization of Near-Infrared Spectrometric Instruments
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this paper, two different approaches are studied for the standardization of near-infrared spectrometric instruments. The first is a simple method based on a univariate slope/bias correction of the predicted values. The second approach proposed is the much more sophisticated piecewise direct standardization (PDS) based on a multivariate correction of spectra. Both standardization methods are applied to three different data sets, and the results obtained are compared. In certain cases, the simple slope/bias correction approach yields results at least as good as those obtained by the PDS procedure. In other cases, the complex PDS procedure is required to obtain acceptable results. A diagnostic tool is developed in order to decide whether the simple slope/bias correction approach can be applied instead of PDS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computer Aided Design of Experiments
Kennard, R. W., & Stone, L. A. (1969) · Technometrics · doi:10.1080/00401706.1969.10490666 · Cited by 3,648
Fuller, W. A. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316665 · Cited by 2,351
Some applications of near-infrared reflectance analysis in the pharmaceutical industry
MacDonald, B. F., & Prebble, K. A. (1993) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(93)80085-f · Cited by 105
Self-citationBouveresse, E., Massart, D. L., & Dardenne, P. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00237-1 · Cited by 101
Self-citation
Cited by
Transfer of multivariate calibration models: a review
Feudale, R. N., Woody, N. A., Tan, H., Myles, A. J., Brown, S. D., & Ferré, J. (2002) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(02)00085-0 · Cited by 555
Cen, H., Lu, R., Zhu, Q., & Mendoza, F. (2016) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2015.09.027 · Cited by 178
The successive projections algorithm for spectral variable selection in classification problems
Pontes, M. J. C., Galvão, R. K. H., Araújo, M. C. U., Moreira, P. N. T., Neto, O. D. P., José, G. E., & Saldanha, T. C. B. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.12.001 · Cited by 177
Long-term stability of a Raman instrument determining iodine value in pork adipose tissue
Olsen, E. F., Baustad, C., Egelandsdal, B., Rukke, E.-O., & Isaksson, T. (2010) · Meat Science · doi:10.1016/j.meatsci.2009.12.008 · Cited by 21
Metadata
- Authors
- Bouveresse, E., Hartmann, C., Massart, D. L., Last, I. R., & Prebble, K. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 6
- Pages
- 982-990
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2069013297
- Cited by
- 246
- References
- 4
- FWCI
- 11.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardization of Near-Infrared Spectrometric Instruments. https://app.cochat.ai/papers/10.1021/ac9510595
- The paper
- Bouveresse, E., Hartmann, C., Massart, D. L., Last, I. R., & Prebble, K. A. (1996). Standardization of Near-Infrared Spectrometric Instruments. Analytical Chemistry. https://doi.org/10.1021/ac9510595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.