Human Norepinephrine Transporter Kinetics Using Rotating Disk Electrode Voltammetry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Rotating disk electrode (RDE) voltammetry is applied to the measurement of the transport of the catecholamine neurotransmitters norepinephrine (4-(2-amino-1-hydroxyethyl)-1,2-benzenediol, NE) and dopamine (3,4-dihydroxyphenethylamine, DA) in suspensions of LLC-NET cells, a line of porcine kidney cells expressing the human norepinephrine transporter (hNET). Initial rate of transport was assessed by following the initial decrease in neurotransmitter after its addition to the cell suspension, as measured by the decrease in oxidation current at +0.45 V vs Ag/AgCl. The initial rate of norepinephrine uptake was saturable, with Vmax and KM of 197 +/- 17 amol min-1 cell-1 and 1.64 +/- 0.46 microM, respectively. The RDE method also allows observation of outward transport (efflux) of the DA or NE previously taken up by the cells. Outward transport was induced by the addition of either d-amphetamine (d-AMPH) or p-tyramine (4-hydroxyphenethylamine, p-TYR), which are also substrates for the NE transporter. The technique was also used to monitor accelerated NE uptake by cells preloaded with p-TYR, a phenomenon distinguishing carriers from channels. Together, these findings document the utility of RDE for the nonisotopic measurement of neurotransmitter influx and efflux from transfected mammalian cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Expression cloning of a cocaine-and antidepressant-sensitive human noradrenaline transporter
Pacholczyk, T., Blakely, R. D., & Amara, S. G. (1991) · Nature · doi:10.1038/350350a0 · Cited by 933
Self-citation
Cited by
Mechanisms of Amphetamine Action Revealed in Mice Lacking the Dopamine Transporter
Jones, S. R., Gainetdinov, R. R., Wightman, R. M., & Caron, M. G. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-06-01979.1998 · Cited by 631
Beitollahi, H., Karimi-Maleh, H., & Khabazzadeh, H. (2008) · Analytical Chemistry · doi:10.1021/ac801854j · Cited by 483
Eisenhofer, G. (2001) · Pharmacology & Therapeutics · doi:10.1016/s0163-7258(01)00144-9 · Cited by 342
Bruchas, M. R., Schindler, A. G., Shankar, H., Messinger, D. I., Miyatake, M., Land, B. B., Lemos, J. C., Hagan, C. E., Neumaier, J. F., Quintana, A., et al. (2011) · Neuron · doi:10.1016/j.neuron.2011.06.011 · Cited by 267
Miller, G. M. (2011) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2010.07109.x · Cited by 249
Metadata
- Authors
- Burnette, W. B., Bailey, M. D., Kukoyi, S., Blakely, R. D., Trowbridge, C. G., & Justice, J. B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-09-01
- Volume
- 68
- Issue
- 17
- Pages
- 2932-2938
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2072180982
- Cited by
- 75
- References
- 1
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.