The DOI matches its Crossref record.
Overoxidized Polypyrrole-Coated Carbon Fiber Microelectrodes for Dopamine Measurements with Fast-Scan Cyclic Voltammetry
Abstract
Thin films of overoxidized polypyrrole have been electro-chemically coated onto carbon fiber microelectrodes and used for dopamine measurements with background-substracted, fast-scan cyclic voltammetry at a scan rate of 300 V/s. The films were stable on the electrode surface only when the electrodes were scanned to high potentials (1400 mV vs SSCE) in pH 7.4 aqueous buffer. Dopamine sensitivity and ascorbate and dihydroxyphenylacetic acid (DOPAC) rejection at the overoxidized polypyrrole-coated electrode were compared to those at carbon fiber electrodes coated with Nafion, a perfluorinated ion-exchange material. At 300 V/s, the overoxidized polypyrrole-coated electrode was almost 3 times more sensitive to dopamine than an uncoated disk electrode. Furthermore, the films were as effective as Nafion in the attenuation of the response to ascorbate and DOPAC, common interferences of dopamine in vivo. Overoxidized polypyrrole-coated electrodes maintained a stable response to dopamine for several hours when implanted in the rat brain. The electrochemical deposition procedure was effective at both elliptical and cylindrical electrodes. This is in contrast to the dip-coating procedures employed with Nafion films that lead to nonuniform coatings at cylindrical electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
The use of nanoparticles in electroanalysis: a review
Welch, C. M., & Compton, R. G. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0230-3 · Cited by 759
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Mo, J.-W., & Ogorevc, B. (2001) · Analytical Chemistry · doi:10.1021/ac0010882 · Cited by 353
Electrochemical nanoarchitectonics and layer-by-layer assembly: From basics to future
Rydzek, G., Ji, Q., Li, M., Schaaf, P., Hill, J. P., Boulmedais, F., & Ariga, K. (2015) · Nano Today · doi:10.1016/j.nantod.2015.02.008 · Cited by 326
Metadata
- Authors
- Pihel, K., Walker, Q. D., & Wightman, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2084-2089
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1992461857
- Cited by
- 251
- References
- 0
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Overoxidized Polypyrrole-Coated Carbon Fiber Microelectrodes for Dopamine Measurements with Fast-Scan Cyclic Voltammetry. https://app.cochat.ai/papers/10.1021/ac960153y
- The paper
- Pihel, K., Walker, Q. D., & Wightman, R. M. (1996). Overoxidized Polypyrrole-Coated Carbon Fiber Microelectrodes for Dopamine Measurements with Fast-Scan Cyclic Voltammetry. Analytical Chemistry. https://doi.org/10.1021/ac960153y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.