The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Simultaneous Measurement of Dopamine and Ascorbate at Their Physiological Levels Using Voltammetric Microprobe Based on Overoxidized Poly(1,2-phenylenediamine)-Coated Carbon Fiber
Abstract
Overoxidized poly-(1,2-phenylenediamine) (OPPD)-coated carbon fiber microelectrodes (CFMEs) exhibit, in combination with square-wave voltammetry (SWV) detection mode, the attractive ability to simultaneously measure low nM dopamine (DA) and mM ascorbate (AA) in a pH 7.4 medium. The PPD polymer film is electrodeposited onto a carbon fiber at a constant potential of 0.8 V versus Ag/AgCl using a solution containing sodium dodecylsulfate as the dopant. After overoxidation using cyclic voltammetry (CV) in the potential range from 0 to 2.2 V at a scan rate of 10 V/s, the resulting OPPD-CFME displays a high SWV current response to cationic DA at approximately 0.2 V and has a favorably low response to anionic AA at approximately 0.0 V vs Ag/AgCl. The preparation of the new OPPD-sensing film has been carefully studied and optimized. The OPPD properties and behavior were characterized using CV and SWV under various conditions and are discussed with respect to DA and AA detection. The linear calibration range for DA in the presence of 0.3 mM AA is 50 nM to 10 microM, with a correlation coefficient of 0.998 and a detection limit of 10 nM using 45-s accumulation. The detection limit for DA in the absence of AA was estimated to be 2 nM (S/N = 3). The linear range for AA in the presence of 100 nM DA is 0.2-2 mM, with a correlation coefficient of 0.999 and a detection limit of 80 microM. The reproducibilities of SWV measurements at OPPD-CFCMEs are 1.6% and 2.5% for 100 nM DA and 0.3 mM AA, respectively. Potential interfering agents, such as 3,4-dihydroxyphenylacetic acid, uric acid, oxalate, human serum proteins, and glucose, at their physiologically relevant or higher concentrations did not have any effect. These favorable features offer great promise for in vitro and in vivo application of the proposed OPPD-coated microprobe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nafion-coated electrodes with high selectivity for CNS electrochemistry
Gerhardt, G. A., Oke, A. F., Nagy, G., Moghaddam, B., & Adams, R. N. (1984) · Brain Research · doi:10.1016/0006-8993(84)90963-6 · Cited by 633
The substantia nigra of the human brain
Damier, P., Hirsch, E. C., Agid, Y., & Graybiel, A. M. (1999) · Brain · doi:10.1093/brain/122.8.1421 · Cited by 578
Gonon, F., Buda, M., Cespuglio, R., Jouvet, M., & Pujol, J.-F. (1980) · Nature · doi:10.1038/286902a0 · Cited by 412
Electrochemical treatment of pyrolytic carbon fiber electrodes
Gonon, F. G., Fombarlet, C. M., Buda, M. J., & Pujol, J. F. (1981) · Analytical Chemistry · doi:10.1021/ac00232a020 · Cited by 404
Principles of voltammetry and microelectrode surface states
Kawagoe, K. T., Zimmerman, J. B., & Wightman, R. M. (1993) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(93)90094-8 · Cited by 394
Parsons, L. H., & Justice, J. B. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb09298.x · Cited by 276
Microvoltammetric techniques and sensors for monitoring neurochemical dynamics in vivo. A review
O'Neill, R. D. (1994) · The Analyst · doi:10.1039/an9941900767 · Cited by 270
o-Phenylenediamine-Modified Carbon Fiber Electrodes for the Detection of Nitric Oxide
Friedemann, M. N., Robinson, S. W., & Gerhardt, G. A. (1996) · Analytical Chemistry · doi:10.1021/ac960093w · Cited by 266
Pihel, K., Walker, Q. D., & Wightman, R. M. (1996) · Analytical Chemistry · doi:10.1021/ac960153y · Cited by 251
Marchmont, R. J., & Houslay, M. D. (1980) · Nature · doi:10.1038/286904a0 · Cited by 146
Cited by
Dopamine biosensor based on surface functionalized nanostructured nickel oxide platform
Roychoudhury, A., Basu, S., & Jha, S. K. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.061 · Cited by 184
Metadata
- Authors
- Mo, J.-W., & Ogorevc, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-02-10
- Volume
- 73
- Issue
- 6
- Pages
- 1196-1202
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2072544666
- Cited by
- 353
- References
- 17
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Measurement of Dopamine and Ascorbate at Their Physiological Levels Using Voltammetric Microprobe Based on Overoxidized Poly(1,2-phenylenediamine)-Coated Carbon Fiber. https://app.cochat.ai/papers/10.1021/ac0010882
- The paper
- Mo, J.-W., & Ogorevc, B. (2001). Simultaneous Measurement of Dopamine and Ascorbate at Their Physiological Levels Using Voltammetric Microprobe Based on Overoxidized Poly(1,2-phenylenediamine)-Coated Carbon Fiber. Analytical Chemistry. https://doi.org/10.1021/ac0010882
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.