The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Phosphopeptide Analysis by Matrix-Assisted Laser Desorption Time-of-Flight Mass Spectrometry
Abstract
In this paper we present methods for identifying and sequencing phosphopeptides in simple mixtures, such as HPLC fractions, at the subpicomole level by (+) ion matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-MS). Data are presented which indicate that when a reflectron time-of-flight mass spectrometer is used, MALDI can distinguish tyrosine phosphorylation from serine and threonine phosphorylation for peptides containing a single phosphate group. Phosphopeptides are identified in the (+) ion MALDI reflector spectrum by the presence of [MH-H3PO4]+ and [MH-HPO3]+ fragment ions formed by metastable decomposition. An abundant [MH-H3PO4]+ ion, accompanied by a weaker [MH-HPO3]+ ion indicates that the peptide is most likely phosphorylated on serine or threonine. In contrast, phosphotyrosine-containing peptides generally exhibit [MH-HPO3]+ fragment ions and little, if any [MH-H3PO4]+. Ambiguities do arise, most often with phosphopeptides that contain residues which readily lose water (such as unmodified serine), but these can often be resolved by recording a complete metastable fragment ion (postsource decay) spectrum. Postsource decay is shown here to be a viable technique for sequencing phosphopeptides. It can be used to distinguish between serine/ threonine and tyrosine phosphorylation and in many cases can be used to determine the exact site of phosphorylation in a peptide sequence. Nearly complete sequence coverage and phosphorylation site mapping is generally possible using approximately 300 fmol of peptide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Techniques in Protein Chemistry
(1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)80012-n · Cited by 1,298
Catalytic specificity of protein-tyrosine kinases is critical for selective signalling
Songyang, Z., Carraway, K. L., Eck, M. J., Harrison, S. C., Feldman, R. A., Mohammadi, M., Schlessinger, J., Hubbard, S. R., Smith, D. P., Eng, C., et al. (1995) · Nature · doi:10.1038/373536a0 · Cited by 919
On target with a new mechanism for the regulation of protein phosphorylation
Hubbard, M. J., & Cohen, P. (1993) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(93)90109-z · Cited by 903
The interpretation of collision‐induced dissociation tandem mass spectra of peptides
Papayannopoulos, I. A. (1995) · Mass Spectrometry Reviews · doi:10.1002/mas.1280140104 · Cited by 657
Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry
Vestal, M. L., Juhasz, P., & Martin, S. A. (1995) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290091115 · Cited by 497
Some Developments in Nuclear Magnetic Resonance of Solids
Chmelka, B. F., & Pines, A. (1989) · Science · doi:10.1126/science.246.4926.71 · Cited by 379
Absolute Values of the Electron Mobility in Hydrogen
Bradbury, N. E., & Nielsen, R. A. (1936) · Physical Review · doi:10.1103/physrev.49.388 · Cited by 340
Enhancement of uphill transport by a double carrier membrane system
Sugawara, M., Omoto, M., Yoshida, H., & Umezawa, Y. (1988) · Analytical Chemistry · doi:10.1021/ac00171a029 · Cited by 320
Structure primaire de la caséine αsl‐bovine: Séquence compléte
Mercier, J., Grosclaude, F., & Ribadeau‐Dumas, B. (1971) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1971.tb01590.x · Cited by 315
Kaufmann, R., Spengler, B., & Lützenkirchen, F. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071010 · Cited by 269
Sequence analysis of phosphoserine‐containing peptides: Modification for picomolar sensitivity
Meyer, H. E., Hoffmann-Posorske, E., Korte, H., & Heilmeyer, L. M. G. (1986) · FEBS Letters · doi:10.1016/0014-5793(86)81388-6 · Cited by 260
Michel, H., Hunt, D. F., Shabanowitz, J., & Bennett, J. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)57275-1 · Cited by 252
Sequential phosphorylation of rhodopsin at multiple sites
Ohguro, H., Palczewski, K., Ericsson, L. H., Walsh, K. A., & Johnson, R. S. (1993) · Biochemistry · doi:10.1021/bi00072a030 · Cited by 205
Jones, E. Y., Harlos, K., Bottomley, M. J., Robinson, R. C., Driscoll, P. C., Edwards, R. M., Clements, J. M., Dudgeon, T. J., & Stuart, D. I. (1995) · Nature · doi:10.1038/373539a0 · Cited by 185
Matrix Dependence of Metastable Fragmentation of Glycoproteins in MALDI TOF Mass Spectrometry
Karas, M., Bahr, U., Strupat, K., Hillenkamp, F., Tsarbopoulos, A., & Pramanik, B. N. (1995) · Analytical Chemistry · doi:10.1021/ac00099a029 · Cited by 169
Spengler, B., Kirsch, D., & KAUFMANN, R. L. (1992) · The Journal of Physical Chemistry · doi:10.1021/j100203a022 · Cited by 145
A manual sequencing method for identification of phosphorylated amino acids in phosphopeptides
Sullivan, S., & Wong, T. W. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90356-x · Cited by 86
Identification of the autophosphorylation sites in rhodopsin kinase.
Palczewski, K., Buczyłko, J., Hooser, P. V., Carr, S. A., Huddleston, M. J., & Crabb, J. W. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)37058-9 · Cited by 74
Self-citationAffolter, M., Watts, J. D., Krebs, D. L., et al. (1994) · Analytical Biochemistry · doi:10.1006/abio.1994.1549 · Cited by 50
Dedner, N., Meyer, H. E., Ashton, C., et al. (1988) · FEBS Letters · doi:10.1016/0014-5793(88)80288-6 · Cited by 47
Insulin-dependent phosphorylation of calmodulin in rat hepatocytes.
Joyal, J. L., & Sacks, D. B. (1994) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)43985-3 · Cited by 27
Approaches to the Practical Use of MS/MS in a Protein Sequencing Facility
Wilm, M. S., Houthaeve, T., Talbo, G. H., et al. (1996) · Humana Press eBooks · doi:10.1007/978-1-4612-0229-5_13 · Cited by 13
Talbo, G., & Mann, M. (1994) · Techniques in protein chemistry · doi:10.1016/b978-0-12-194710-1.50017-5 · Cited by 13
Cited by
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Immobilized Gallium(III) Affinity Chromatography of Phosphopeptides
Posewitz, M. C., & Tempst, P. (1999) · Analytical Chemistry · doi:10.1021/ac981409y · Cited by 832
Tanner, K. G., Landry, J., Sternglanz, R., & Denu, J. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.250422697 · Cited by 555
Zhao, J., Du, Y., Horton, J. R., Upadhyay, A. K., Lou, B., Bai, Y., Zhang, X., Du, L., Li, M., Wang, B., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100012108 · Cited by 105
Lim, A., Prokaeva, T., McComb, M. E., O'Connor, P. B., Théberge, R., Connors, L. H., Skinner, M., & Costello, C. E. (2002) · Analytical Chemistry · doi:10.1021/ac010780+ · Cited by 63
Metadata
- Authors
- Annan, R. S., & Carr, S. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-10-01
- Volume
- 68
- Issue
- 19
- Pages
- 3413-3421
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2071106732
- Cited by
- 310
- References
- 24
- FWCI
- 9.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.