The DOI matches its Crossref record.
Octadecylsilylated Porous Silica Rods as Separation Media for Reversed-Phase Liquid Chromatography
Abstract
Continuous porous silica rods consisting of a mesoporous (pore size, 14 or 25 nm) silica skeleton of ∼1 μm size and through-pores of ∼1.7 μm were prepared and derivatized to C(18) phase by on-column reaction with octadecyldimethyl-(N,N-diethylamino)silane. The C(18) silica rods gave plate heights of 10-20 μm for aromatic hydrocarbons in 80% methanol and 20-40 μm for insulin in acetonitrile-water mixtures in the presence of trifluoroacetic acid. The performance of the silica rods was much better at a high flow rate than that of conventional columns packed with 5 μm C(18) silica particles having 12 and 30 nm pores, especially for high molecular weight species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sun, M.-H., Huang, S.-Z., Chen, L.-H., Li, Y., Yang, X.-Y., Yuan, Z.-Y., & Su, B.-L. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00135a · Cited by 1,454
Fast analysis in liquid chromatography using small particle size and high pressure
Nguyen, D. T. ‐., Guillarme, D., Rudaz, S., & Veuthey, J. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600189 · Cited by 337
Carbon Aerogels and Monoliths: Control of Porosity and Nanoarchitecture via Sol–Gel routes
Antonietti, M., Fechler, N., & Fellinger, T.-P. (2014) · Chemistry of Materials · doi:10.1021/cm402239e · Cited by 227
Metadata
- Authors
- Minakuchi, H., Nakanishi, K., Soga, N., Ishizuka, N., & Tanaka, N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-10-01
- Volume
- 68
- Issue
- 19
- Pages
- 3498-3501
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2070457128
- Cited by
- 904
- References
- 0
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.