CoChat

Accuracy Requirements for Peptide Characterization by Monoisotopic Molecular Mass Measurements

Zubarev, Roman A., Håkansson, Per, Sundqvist, Bo · 1996 · Analytical Chemistry
Cited by 126

The DOI matches its Crossref record.

Abstract

Accurately measured monoisotopic mass of a biomolecule can reveal its elemental and, in the case of a biopolymer, its monomer composition. In this work, the limitations of the technique were analyzed in application to peptides. For the currently available level of mass accuracy of about ±1 ppm, the mass limit for revealing the unique elemental composition of a peptide was found to be 700−800 Da, with the possibility to extend this range as the mass accuracy improves. As for the amino acid composition determination, the principal limit of ∼500−600 Da cannot be overcome in the general case by instrumental or methodological improvements. It is proposed that, for the peptide characterization, the molecular mass must be determined with sufficient accuracy to rule out a significant fraction of the peptides having the same nominal mass but different elemental and amino acid compositions. An accuracy of ±1 ppm was found to exclude 99% of such peptides and, therefore, ensure a high degree of confidence in peptide characterization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9604651

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Zubarev, R. A., Håkansson, P., & Sundqvist, B.
Venue
Analytical Chemistry
Published
1996-01-01
Volume
68
Issue
22
Pages
4060-4063
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2093994728
Cited by
126
References
0
FWCI
1.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.