The DOI matches its Crossref record.
Automated In-Tube Solid-Phase Microextraction Coupled to High-Performance Liquid Chromatography
Abstract
Recently, solid-phase microextraction (SPME) was successfully coupled to high-performance liquid chromatography. However, the efficiency of this analytical method, in terms of manpower, still suffers from its manual operation technique. Furthermore, the selectivity obtained for the analysis of very polar compounds is still poor because of a limited selection of commercially available fiber coatings that can withstand the aggressive HPLC conditions (solvents). This paper describes the first approach to developing an automated SPME-HPLC system. A mixture of polar thermally labile analytes, phenylurea pesticides, was selected for microextraction directly from an aqueous sample. A piece of a ordinary capillary GC column with its coating (Omegawax 250) was used for the absorption of analytes from the aqueous sample (in-tube solid-phase microextraction). A needle hosts the capillary when it is pierced through the septum of the vial containing the spiked aqueous sample. The aqueous samples were stored in 2 mL vials on the tray of a commercial autosampler. A sample of 25 μL was aspirated and dispensed several times from the sample into the capillary using a syringe. After the extraction the absorbed analytes were released from the coating by aspiring methanol into the column and then dispensing the methanol into the HPLC injector loop. The absorption−time profiles, the amounts absorbed by different coatings, linearity, and precision were studied under different sampling conditions using spiked aqueous samples. SPME selectivity for polar compounds, which represent an important compound class for water analysis, can be improved by using more polar column coatings such as Carbowax instead of poly(dimethylsiloxane)-coated columns. Compared to the manual version this automated SPME-HPLC system could increase productivity and reproducibility. Furthermore, the desorption step is quantitative; i.e., no carryover could be detected. This entire method for automated SPME sample preparation is simple and controlled by a commercial autosampler from LC Packings which was modified to operate in-tube SPME. The automated SPME-HPLC device obtains RSD for all investigated compounds below 6%. A simple mathematical model was used to calculate the concentrations vs length profiles in the column for any time. The model was in good agreement with experimental data which was obtained for benzene as a model compound. Thus, the main parameters affecting the partitioning process were determined and the amount absorbed by the coating could be predicted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Self-citationChen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Sosa Ferrera, Z., Padrón Sanz, C., Mahugo Santana, C., & Santana Rodrı́guez, J. J. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00732-0 · Cited by 184
The roles of ionic liquids in sorptive microextraction techniques
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.11.009 · Cited by 171
Analytical Microextraction: Current Status and Future Trends
Pawliszyn, J., & Pedersen-Bjergaard, S. (2006) · Journal of Chromatographic Science · doi:10.1093/chromsci/44.6.291 · Cited by 123
Self-citation
Metadata
- Authors
- Eisert, R., & Pawliszyn, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-08-01
- Volume
- 69
- Issue
- 16
- Pages
- 3140-3147
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2005431617
- Cited by
- 547
- References
- 0
- FWCI
- 17.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated In-Tube Solid-Phase Microextraction Coupled to High-Performance Liquid Chromatography. https://app.cochat.ai/papers/10.1021/ac970319a
- The paper
- Eisert, R., & Pawliszyn, J. (1997). Automated In-Tube Solid-Phase Microextraction Coupled to High-Performance Liquid Chromatography. Analytical Chemistry. https://doi.org/10.1021/ac970319a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.