CoChat

High Temporal Resolution Monitoring of Glutamate and Aspartate in Vivo Using Microdialysis On-Line with Capillary Electrophoresis with Laser-Induced Fluorescence Detection

Lada, Mark W., Vickroy, Thomas W., Kennedy, Robert T. · 1997 · Analytical Chemistry
Cited by 169

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

An automated method for high temporal resolution monitoring of the neurotransmitters glutamate and aspartate in vivo using capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was developed. Microdialysis probes placed in the striatum of anesthetized rats were coupled on-line with the CE system by an automated flow-gated interface. Analytes were derivatized on-line with o-phthaldialdehyde/beta-mercaptoethanol and detected by LIF using the 354 nm line (7 mW) of a He-Cd laser for excitation. With dialysis flow rates of 1.2 microL/ min, the detection limit at the dialysis probe was 200 nM for glutamate and aspartate. Glutamate and aspartate could be resolved in less than 5 s with over 200,000 theoretical plates. The sampling time was limited by the separation time while the temporal resolution was limited to approximately 12 s because of band broadening that occurs within the probe and its associated tubing. The high temporal resolution allowed the first simultaneous monitoring of glutamate and aspartate overflow during acute electrical stimulation in the rat brain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac970518u

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 169

Metadata

Authors
Lada, M. W., Vickroy, T. W., & Kennedy, R. T.
Venue
Analytical Chemistry
Published
1997-11-01
Volume
69
Issue
22
Pages
4560-4565
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1984784421
Cited by
169
References
12
FWCI
8.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.