Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Theoretical Justification of Wavelength Selection in PLS Calibration: Development of a New Algorithm

Spiegelman, Clifford H., McShane, Michael J., Goetz, Marcel J., Motamedi, Massoud, Yue, Qin Li, Coté, Gerard L.·1998·Analytical Chemistry

Abstract

The mathematical basis of improved calibration through selection of informative variables for partial least-squares calibration has been identified. A theoretical investigation of calibration slopes indicates that including uninformative wavelengths negatively affect calibrations by producing both large relative bias toward zero and small additive bias away from the origin. These theoretical results are found regardless of the noise distribution in the data. Studies are performed to confirm this result using a previously used selection method compared to a new method, which is designed to perform more appropriately when dealing with data having large outlying points by including estimates of spectral residuals. Three different data sets are tested with varying noise distributions. In the first data set, Gaussian and log-normal noise was added to simulated data which included a single peak. Second, near-infrared spectra of glucose in cell culture media taken with an FT-IR spectrometer were analyzed. Finally, dispersive Raman Stokes spectra of glucose dissolved in water were assessed. In every case considered here, improved prediction is produced through selection, but data with different noise characteristics showed varying degrees of improvement depending on the selection method used. The practical results showed that, indeed, including residuals into ranking criteria improves selection for data with noise distributions resulting in large outliers. It was concluded that careful design of a selection algorithm should include consideration of spectral noise distributions in the input data to increase the likelihood of successful and appropriate selection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9705733

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 261

Metadata

Authors
Spiegelman, C. H., McShane, M. J., Goetz, M. J., Motamedi, M., Yue, Q. L., & Coté, G. L.
Venue
Analytical Chemistry
Published
1998-01-01
Volume
70
Issue
1
Pages
35-44
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2026398748
Cited by
261
References
12
FWCI
14.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Theoretical Justification of Wavelength Selection in PLS Calibration: Development of a New Algorithm. https://app.cochat.ai/papers/10.1021/ac9705733
The paper
Spiegelman, C. H., McShane, M. J., Goetz, M. J., Motamedi, M., Yue, Q. L., & Coté, G. L. (1998). Theoretical Justification of Wavelength Selection in PLS Calibration: Development of a New Algorithm. Analytical Chemistry. https://doi.org/10.1021/ac9705733

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.