The DOI matches its Crossref record.
Interval Partial Least-Squares Regression (i PLS): A Comparative Chemometric Study with an Example from Near-Infrared Spectroscopy
Abstract
A new graphically oriented local modeling procedure called interval partial least-squares ( iPLS) is presented for use on spectral data. The iPLS method is compared to full-spectrum partial least-squares and the variable selection methods principal variables (PV), forward stepwise selection (FSS), and recursively weighted regression (RWR). The methods are tested on a near-infrared (NIR) spectral data set recorded on 60 beer samples correlated to original extract concentration. The error of the full-spectrum correlation model between NIR and original extract concentration was reduced by a factor of 4 with the use of iPLS ( r = 0.998, and root mean square error of prediction equal to 0.17% plato), and the graphic output contributed to the interpretation of the chemical system under observation. The other methods tested gave a comparable reduction in the prediction error but suffered from the interpretation advantage of the graphic interface. The intervals chosen by iPLS cover both the variables found by FSS and all possible combinations as well as the variables found by PV and RWR, and iPLS is still able to utilize the first-order advantage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cai, W., Li, Y., & Shao, X. (2008) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2007.10.001 · Cited by 573
Quantitative Analysis Using Raman Spectrometry
Pelletier, M. J. (2003) · Applied Spectroscopy · doi:10.1366/000370203321165133 · Cited by 435
Rasmussen, L. G., Winning, H., Savorani, F., Toft, H., Larsen, T. M., Dragsted, L. O., Astrup, A., & Engelsen, S. B. (2012) · Nutrients · doi:10.3390/nu4020112 · Cited by 81
Feidl, F., Garbellini, S., Vogg, S., Sokolov, M., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2019) · Biotechnology Progress · doi:10.1002/btpr.2847 · Cited by 59
Mancini, M., Rinnan, Å., Pizzi, A., Mengarelli, C., Rossini, G., Duca, D., & Toscano, G. (2018) · Fuel · doi:10.1016/j.fuel.2018.01.008 · Cited by 33
Metadata
- Authors
- Nørgaard, L., Saudland, A., Wagner, J., Nielsen, J. P., Munck, L., & Engelsen, S. B.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2000-03
- Volume
- 54
- Issue
- 3
- Pages
- 413-419
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2007808016
- Cited by
- 1,361
- References
- 0
- FWCI
- 12.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interval Partial Least-Squares Regression (i PLS): A Comparative Chemometric Study with an Example from Near-Infrared Spectroscopy. https://app.cochat.ai/papers/10.1366/0003702001949500
- The paper
- Nørgaard, L., Saudland, A., Wagner, J., Nielsen, J. P., Munck, L., & Engelsen, S. B. (2000). Interval Partial Least-Squares Regression (i PLS): A Comparative Chemometric Study with an Example from Near-Infrared Spectroscopy. Applied Spectroscopy. https://doi.org/10.1366/0003702001949500
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.