The DOI matches its Crossref record.
Intelligent Polymerized Crystalline Colloidal Arrays: Novel Chemical Sensor Materials
Abstract
We report the development of a novel sensing material that reports on analyte concentrations via diffraction of visible light from a polymerized crystalline colloidal array (PCCA). The PCCA is a mesoscopically periodic crystalline colloidal array (CCA) of spherical polystyrene colloids polymerized within a thin, intelligent polymer hydrogel film. CCAs are brightly colored, and they efficiently diffract visible light meeting the Bragg condition. The intelligent hydrogel incorporates chemical molecular recognition agents that cause the gel to swell in response to the concentration of particular analytes; the gel volume is a function of the analyte concentration. The color diffracted from the hydrogel film is, thus, a function of analyte concentration: the swelling of the gel changes the periodicity of the CCA, which results in a shift in the diffracted wavelength. We have fabricated a sensor, utilizing a crown ether as the recognition agent, that detects Pb 2+ in the 0.1 μM−20mM (∼20 ppb−∼4000 ppm) concenration range. We have also fabricated glucose and galactose sensors, utilizing glucose oxidase or β- d -galactosidase as the recognition elements. The glucose oxidase sensor detects glucose in the 0.1−0.5 mM (18−90 ppm) concentration range in the presence of oxygen and detects as little as 10 - 12 M glucose (0.18 ppt) in the absence of oxygen. In addition, this sensor reports on dissolved oxygen concentration from ∼1 to 6 ppm in the presence of constant glucose concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photonic-crystal full-colour displays
Arsenault, A. C., Puzzo, D. P., Manners, I., & Ozin, G. A. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.140 · Cited by 914
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
Colorful humidity sensitive photonic crystal hydrogel
Tian, E., Wang, J., Zheng, Y., Song, Y., Jiang, L., & Zhu, D. (2008) · Journal of Materials Chemistry · doi:10.1039/b717368g · Cited by 344
Fast Responsive Crystalline Colloidal Array Photonic Crystal Glucose Sensors
Ben-Moshe, M., Alexeev, V. L., & Asher, S. A. (2006) · Analytical Chemistry · doi:10.1021/ac060643i · Cited by 292
Self-citationTwo-Dimensional Photonic Crystal Chemical and Biomolecular Sensors
Cai, Z., Smith, N. L., Zhang, J.-T., & Asher, S. A. (2015) · Analytical Chemistry · doi:10.1021/ac504679n · Cited by 216
Self-citation
Metadata
- Authors
- Holtz, J. H., Holtz, J. S. W., Munro, C. H., & Asher, S. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-01-21
- Volume
- 70
- Issue
- 4
- Pages
- 780-791
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2031802551
- Cited by
- 301
- References
- 0
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intelligent Polymerized Crystalline Colloidal Arrays: Novel Chemical Sensor Materials. https://app.cochat.ai/papers/10.1021/ac970853i
- The paper
- Holtz, J. H., Holtz, J. S. W., Munro, C. H., & Asher, S. A. (1998). Intelligent Polymerized Crystalline Colloidal Arrays: Novel Chemical Sensor Materials. Analytical Chemistry. https://doi.org/10.1021/ac970853i
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.