The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Surface Plasmon Resonance Imaging Measurements of DNA Hybridization Adsorption and Streptavidin/DNA Multilayer Formation at Chemically Modified Gold Surfaces
Abstract
A combination of scanning and imaging surface plasmon resonance (SPR) experiments is used to characterize DNA hybridization adsorption at gold surfaces and the subsequent immobilization of streptavidin. Single-stranded oligonucleotides are immobilized at gold surfaces, and the hybridization of biotinylated complements from solution is monitored with SPR. The subsequent attachment of streptavidin to the biotinylated complements provides a method of enhancing the SPR imaging signal produced as a result of the hybridization and leads to a 4-fold improvement in the hybridization detection limit of the SPR imaging apparatus. In situ scanning SPR experiments are used to measure a 60 ± 20% hybridization efficiency between immobilized single-stranded DNA and biotinylated complements. From the information provided by both the in situ imaging and scanning SPR experiments, an absolute surface coverage of immobilized single-stranded DNA is estimated to be ∼3 × 10 12 molecules/cm 2 . The SPR signal resulting from hybridization onto immobilized probes is further amplified by the formation of streptavidin/DNA multilayers which grow by a combination of DNA hybridization and biotin−streptavidin binding. DNA/DNA multilayers without streptavidin are used as an additional method of amplifying the SPR signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
Cited by
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
A unified view of propagating and localized surface plasmon resonance biosensors
Haes, A. J., & Van Duyne, R. P. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2708-9 · Cited by 666
Liu, Q., Wang, L., Frutos, A. G., Condon, A. E., Corn, R. M., & Smith, L. M. (2000) · Nature · doi:10.1038/35003155 · Cited by 529
Self-citationSurface plasmon resonance based biosensor technique: A review
Guo, X. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200015 · Cited by 436
Wijaya, E., Lenaerts, C., Maricot, S., Hastanin, J., Habraken, S., Vilcot, J.-P., Boukherroub, R., & Szunerits, S. (2011) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2011.05.001 · Cited by 377
Detection of single-base DNA mutations by enzyme-amplified electronic transduction
Patolsky, F., Lichtenstein, A., & Willner, I. (2001) · Nature Biotechnology · doi:10.1038/85704 · Cited by 368
Impedance-based detection of DNA sequences using a silicon transducer with PNA as the probe layer
Macanovic, A. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh003 · Cited by 309
Surface Plasmon Resonance Imaging Sensors: A Review
Wong, C. L., & Olivo, M. (2014) · Plasmonics · doi:10.1007/s11468-013-9662-3 · Cited by 259
CHORLEY, B., WANG, X., CAMPBELL, M., PITTMAN, G., NOUREDDINE, M., & BELL, D. (2008) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2008.05.001 · Cited by 177
Metadata
- Authors
- Jordan, C. E., Frutos, A. G., Thiel, A. J., & Corn, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-12-01
- Volume
- 69
- Issue
- 24
- Pages
- 4939-4947
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2073773592
- Cited by
- 281
- References
- 1
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.