Oxygen Isotope Analysis of Cellulose: An Interlaboratory Comparison
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Oxygen isotope analysis of tree ring cellulose is hindered by the lack of a fast and reliable technique to measure δ 18 O at natural abundance levels. Most of the existing off-line techniques are not conducive to rapid generation of oxygen isotope data. Further, a comparison between oxygen isotope values of a cellulose sample measured using the different off-line techniques resulted in a discrepancy of 1.3‰. This discrepancy is a result of inconsistencies inherent to these techniques and the lack of a reliable cellulose oxygen isotope standard. We addressed these problems by analyzing a number of cellulose samples by three different analytical procedures. These include two relatively well established off-line methods (pyrolysis in nickel tubes and decomposition using mercury(II) chloride) and a recently proposed on-line method based on pyrolysis in the presence of glassy carbon in an elemental analyzer and the subsequent isotope analysis of carbon monoxide. We were successful in improving the reproducibility of the on-line method (σ n - 1 ≈0.2‰) to the extent that natural variations can be resolved and found a good agreement between the on-line and off-line methods, although the cellulose samples extracted from tree rings are subject to more scatter than the commercial cellulose samples. The on-line method may even allow determination of δ 13 C and δ 18 O of a cellulose sample in a single run (from 29/28 and 30/28 ratios of CO).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On-line determination of δ18O values of organic substances
Werner, R. A., Kornexl, B. E., Roβmann, A., & Schmidt, H.-L. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00468-8 · Cited by 108
Adaptation of the unterzaucher procedure for determination of Oxygen-18 in organic substances
Santrock, J., & Hayes, J. M. (1987) · Analytical Chemistry · doi:10.1021/ac00128a025 · Cited by 57
Cited by
McCarroll, D., & Loader, N. J. (2004) · Quaternary Science Reviews · doi:10.1016/j.quascirev.2003.06.017 · Cited by 1,817
A mechanistic model for interpretation of hydrogen and oxygen isotope ratios in tree-ring cellulose
Roden, J. S., Lin, G., & Ehleringer, J. R. (2000) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(99)00195-7 · Cited by 794
Boettger, T., Haupt, M., Knöller, K., Weise, S. M., Waterhouse, J. S., Rinne, K. T., Loader, N. J., Sonninen, E., Jungner, H., Masson-Delmotte, V., et al. (2007) · Analytical Chemistry · doi:10.1021/ac0700023 · Cited by 221
Self-citationTree-ring isotope records of tropical cyclone activity
Miller, D. L., Mora, C. I., Grissino-Mayer, H. D., Mock, C. J., Uhle, M. E., & Sharp, Z. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606549103 · Cited by 212
Ménot, G., & Burns, S. J. (2001) · Organic Geochemistry · doi:10.1016/s0146-6380(00)00170-4 · Cited by 158
Leuenberger, M. C., & Filot, M. S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2998 · Cited by 37
Self-citationYoung, G. H. F., Loader, N. J., & McCarroll, D. (2011) · Palaeogeography, Palaeoclimatology, Palaeoecology · doi:10.1016/j.palaeo.2010.11.018 · Cited by 24
Metadata
- Authors
- Saurer, M., Robertson, I., Siegwolf, R., & Leuenberger, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-04-18
- Volume
- 70
- Issue
- 10
- Pages
- 2074-2080
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010243312
- Cited by
- 137
- References
- 2
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.