The DOI matches its Crossref record.
Matrix Effect in Quantitative LC/MS/MS Analyses of Biological Fluids: A Method for Determination of Finasteride in Human Plasma at Picogram Per Milliliter Concentrations
Abstract
Contrary to common perceptions, the reliability of quantitative assays for the determination of drugs in biological fluids using high-performance liquid chromatography with tandem mass spectrometric (LC/MS/MS) detection methods and the integrity of resulting pharmacokinetic data may not be absolute. Results may be adversely affected by lack of specificity and selectivity due to ion suppression caused by the sample matrix, interferences from metabolites, and "cross-talk" effects. In this paper, an example of the effect of the sample matrix on the determination of finasteride (I) in human plasma is presented. The ion suppression effect was studied by analyzing standards of I injected directly in mobile phase and comparing the response (peak areas) of I and an internal standard (II) with the peak areas of the same analytes spiked before extraction into five different plasma pools and standards spiked into the plasma extracts after extraction. The LC/MS/MS analyses were performed using a turbo ion spray interface (TISP) under chromatographic conditions, characterized by minimal (total run time of 2 min, capacity factors, k' of 1.50 and 1.75 for I and II, respectively) and high retention of the analytes (total run time 6 min, k' of 3.25 and 13.25 for I and II, respectively). The absolute peak areas for I and II in different plasmas were calculated, and the slopes and peak area ratios at all concentrations within the standard curve ranges were compared. When analyses were performed under conditions of minimal HPLC retention, the slope of the standard line for one set of plasma samples was substantially different (about 50% higher) from that from other plasma sources. The precision of the assay, expressed as coefficient of variation (CV, %) was also inadequate and varied from 15 to 30% at all concentrations within the standard curve range. When the same experiments were repeated using high HPLC retention, the slopes from different plasma sources were practically the same, and the CV was improved to 6-14%. By increasing k' and providing more chromatographic retention of analytes, the "unseen" interferences from plasma matrix were mostly separated from analytes, practically eliminating the ion suppression. In addition, by eliminating from plasma extracts a number of endogenous components through more selective extraction, the ion suppression was also minimized. The detailed data and the design of these experiments are presented. In addition, development of a highly sensitive assay for I in human plasma at low picogram per milliliter concentrations using LC/MS/MS with a heated nebulizer (HN) interface, instead of a TISP interface, is described. In this case, the effects of sample matrixes were not observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Carr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Ferrer, C., Lozano, A., Agüera, A., Girón, A. J., & Fernández-Alba, A. R. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.033 · Cited by 485
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
LC/MS analysis of stratum corneum lipids: ceramide profiling and discovery
van Smeden, J., Hoppel, L., van der Heijden, R., Hankemeier, T., Vreeken, R. J., & Bouwstra, J. A. (2011) · Journal of Lipid Research · doi:10.1194/jlr.m014456 · Cited by 229
Metadata
- Authors
- Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-02-04
- Volume
- 70
- Issue
- 5
- Pages
- 882-889
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2040308794
- Cited by
- 880
- References
- 0
- FWCI
- 49.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Matrix Effect in Quantitative LC/MS/MS Analyses of Biological Fluids: A Method for Determination of Finasteride in Human Plasma at Picogram Per Milliliter Concentrations. https://app.cochat.ai/papers/10.1021/ac971078+
- The paper
- Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998). Matrix Effect in Quantitative LC/MS/MS Analyses of Biological Fluids: A Method for Determination of Finasteride in Human Plasma at Picogram Per Milliliter Concentrations. Analytical Chemistry. https://doi.org/10.1021/ac971078%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.