CoChat

Bioelectrochemical Monitoring of Phenols and Aromatic Amines in Flow Injection Using Novel Plant Peroxidases

Munteanu, Florentina-Daniela, Lindgren, Annika, Emnéus, Jenny, Gorton, Lo, Ruzgas, Tautgirdas, Csöregi, Elisabeth, Ciucu, Anton, van Huystee, R. B., Gazaryan, Irina G., Lagrimini, L. Mark · 1998 · Analytical Chemistry
Cited by 120

The DOI matches its Crossref record.

Abstract

An amperometric flow system combined with a glucose oxidase-mutarotase reactor was optimized and used to determine aromatic amines and phenols using peroxidase-modified graphite electrodes. An increase in currents upon injection of the analyzed substrate was shown to be approximated by a Michaelis-Menten type dependence. The detection limit was calculated as 3 times the noise, and the sensitivity was calculated as Imax/K(m)app. Commercially available horseradish peroxidase was compared with tobacco anionic and peanut cationic peroxidases for determination of aromatic amines and phenols. Detection limits of 10 nM for determination of o-aminophenol and o- and p-phenylenediamine achieved with a tobacco peroxidase-modified electrode give a promise for further improvements in sensitivities and detection limits of biosensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac980022s

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Munteanu, F.-D., Lindgren, A., Emnéus, J., Gorton, L., Ruzgas, T., Csöregi, E., Ciucu, A., van Huystee, R. B., Gazaryan, I. G., & Lagrimini, L. M.
Venue
Analytical Chemistry
Published
1998-05-09
Volume
70
Issue
13
Pages
2596-2600
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2003534913
Cited by
120
References
0
FWCI
4.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.