CoChat

Phase Correction for Collision Model Analysis and Enhanced Resolving Power of Fourier Transform Ion Cyclotron Resonance Mass Spectra

Vining, Bryan A., Bossio, Robert E., Marshall, Alan G. · 1999 · Analytical Chemistry
Cited by 34

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Phase correction of FT-ICR data yields an absorption spectrum that offers a gain by up to a factor of 2 in mass resolving power (at half-maximum peak height), compared to conventional magnitude-mode display. That improvement is equivalent to doubling the applied magnetic field strength, without loss in signal-to-noise (S/N) ratio, provided that the time-domain data are padded with an equal number of zeroes before FFT. Our simple, visual, user-interactive algorithm quickly corrects for zero-order and first-order variation of phase with frequency. We find that the theoretical mass resolving power enhancement for pressure-limited absorption-mode over magnitude-mode line shape depends on the collision mechanism: factor of 1.40 for hard sphere vs 3(1/2) for Langevin (ion: induced dipole). Thus, the experimental enhancement in mass resolving power (factor of 1.43 +/- 0.09) for isotopically resolved peaks in the FT-ICR mass spectra of electrosprayed bovine carbonic anhydrase (approximately 29 kDa) directly supports the hard-sphere collision model. Optimal implementation of phasing requires the following: (a) a delay between excitation and detection of less than half of one sampling interval to avoid baseline "roll" and Gibb's oscillations; (b) accurate analog-to-digital conversion; (c) a sufficiently long acquisition period to yield several data points per absorption-mode peak width at half-maximum peak height; and (d) avoidance of FT-ICR apodization functions (e.g., Hamming and Hanning) that suppress the initial time-domain data. Pulsed single-frequency excitation (duration much less than the reciprocal of the Nyquist bandwidth) can eliminate higher than first-order variation of phase with frequency. Phased FT-ICR spectra should prove especially desirable for analysis of complex mixtures, for resolving isotopic distributions in electrosprayed multiply charged macromolecules and for characterizing ion collisions (and thus ion size and shape).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9808019

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 34

Metadata

Authors
Vining, B. A., Bossio, R. E., & Marshall, A. G.
Venue
Analytical Chemistry
Published
1998-12-04
Volume
71
Issue
2
Pages
460-467
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2006832045
Cited by
34
References
1
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.