The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Universal Concept for Stacking Neutral Analytes in Micellar Capillary Electrophoresis
Abstract
Unlike recent studies that have depended on manipulation of separation buffer parameters to facilitate stacking of neutral analytes in micellar capillary electrophoresis (MCE) mode, we have developed a method of stacking based simply on manipulation of the sample matrix. Many solutions for sample stacking in MCE are based on strict control of pH, micelle type, electroosmotic flow (EOF) rate, and separation-mode polarity. However, a universal solution to sample stacking in MCE should allow for free manipulation of separation buffer parameters without substantially affecting separation of analytes. Analogous to sample stacking in capillary zone electrophoresis by invoking field amplification of charged analytes in a low-conductivity sample matrix, the proposed method utilizes a high-conductivity sample matrix to transfer field amplification from the sample zone to the separation buffer. This causes the micellar carrier in the separation buffer to stack before it enters the sample zone. Neutral analytes moving out of the sample zone with EOF are efficiently concentrated at the micelle front. Micelle stacking is induced by simply adding salt to the sample matrix to increase the conductivity 2-3-fold higher than the separation buffer. This solution allows free optimization of separation buffer parameters such as micelle concentration, organic modifiers, and pH, providing a method that may complement virtually any existing MCE protocol without restricting the separation method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increased Vascularization in Mice Overexpressing Angiopoietin-1
Suri, C., McClain, J., Thurston, G., McDonald, D. M., Zhou, H., Oldmixon, E. H., Sato, T. N., & Yancopoulos, G. D. (1998) · Science · doi:10.1126/science.282.5388.468 · Cited by 818
Cited by
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
On-line sample preconcentration in capillary electrophoresis
Simpson, S. L., Quirino, J. P., & Terabe, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.001 · Cited by 342
Britz-McKibbin, P., & Chen, D. D. Y. (2000) · Analytical Chemistry · doi:10.1021/ac990898e · Cited by 310
Metadata
- Authors
- Palmer, J., Munro, N. J., & Landers, J. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-04-01
- Volume
- 71
- Issue
- 9
- Pages
- 1679-1687
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2055521355
- Cited by
- 217
- References
- 1
- FWCI
- 20.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.