The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Selective Focusing of Catecholamines and Weakly Acidic Compounds by Capillary Electrophoresis Using a Dynamic pH Junction
Abstract
A systematic study of selective analyte focusing in a multisection electrolyte system by capillary electrophoresis (CE) is presented. It was found that a dynamic pH junction between sample and background electrolyte zones can be used to focus zwitterionic catecholamines and weakly acidic compounds without the use of special ampholytes. Differences in pH and concentration of complexing agents, such as borate, in the sample and background electrolyte zones were determined to cause focusing through changes in the local velocity of the analyte in two different segments of the capillary. Velocity-difference induced focusing (V-DIF) of analytes using a dynamic pH junction allowed the injection of large sample volumes and significantly improved the concentration sensitivity of CE. Under optimized conditions, the limit of detection for epinephrine was determined to be about 4 x 10(-8) M (the original sample) with conventional UV absorbance detection. Moreover, separation efficiencies greater than a million theoretical plates can be achieved by focusing such large sample volumes into narrow zones. Multisection electrolyte systems, which lead to the formation of a dynamic pH junction, can be tuned toward improving the concentration sensitivity of specific analytes if their chemical properties are known.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exceeding 5000-Fold Concentration of Dilute Analytes in Micellar Electrokinetic Chromatography
Quirino, J. P., & Terabe, S. (1998) · Science · doi:10.1126/science.282.5388.465 · Cited by 644
Sample stacking of an extremely large injection volume in high-performance capillary electrophoresis
Chien, R. L., & Burgi, D. S. (1992) · Analytical Chemistry · doi:10.1021/ac00033a015 · Cited by 509
Sample self-stacking in zone electrophoresis
Gebauer, P., Thormann, W., & Boc̆ek, P. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)87104-g · Cited by 224
A Universal Concept for Stacking Neutral Analytes in Micellar Capillary Electrophoresis
Palmer, J., Munro, N. J., & Landers, J. P. (1999) · Analytical Chemistry · doi:10.1021/ac981302a · Cited by 217
Analysis of dilute peptide samples by capillary zone electrophoresis
Aebersold, R., & Morrison, H. D. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)90206-7 · Cited by 179
Sensitivity Enhancement for Capillary Electrophoresis
ALBIN, M. W., Grossman, P. D., & Moring, S. E. (1993) · Analytical Chemistry · doi:10.1021/ac00058a720 · Cited by 125
Bergquist, J., Josefsson, E., Tarkowski, A., et al. (1997) · Electrophoresis · doi:10.1002/elps.1150181009 · Cited by 105
Epinephrine in the central nervous system
Stolk, J. M., U’Prichard, D. C., & Fuxé, K. (1988) · Oxford University Press eBooks · Cited by 102
Oriented Immobilization of Fab' Fragments on Silica Surfaces
Lü, B., Xie, J., Lu, C., et al. (1995) · Analytical Chemistry · doi:10.1021/ac00097a014 · Cited by 97
Hadwiger, M. E., Torchia, S. R., Park, S., Biggin, M. E., & Lunte, C. E. (1996) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/0378-4347(95)00549-8 · Cited by 93
Research works printed but not linked: 28
- Terabe S., 1989, Anal. Chem., 61, 60, 10.1021/ac00178a013 · doi:10.1021/ac00178a013
- Burgi D. S., 1992, Anal. Biochem., 202, 9, 10.1016/0003-2697(92)90110-S · doi:10.1016/0003-2697(92)90110-s
- Burgi D. S., 1993, Anal. Chem., 65, 29, 10.1021/ac00072a030 · doi:10.1021/ac00072a030
- Chien R., 1991, J. Chromatogr., 559, 152
- Quirino J. P., 1998, Anal. Chem., 70, 157, 10.1021/ac982221h · doi:10.1021/ac982221h
- Quirino J. P., 1998, Anal. Chem., 70, 1901
- McGrath G., 1996, J. Chromatogr., B, 681, 131, 10.1016/0378-4347(95)00486-6 · doi:10.1016/0378-4347(95)00486-6
- Geldart S. E., 1997, Lab
- Deforce D. L. D., 1996, Anal. Chem., 68, 84
- Wolf S. M., 1995, Anal. Chem., 67, 900
- Zhang J., 1995, J. Anal. Chem., 67, 93, 10.1021/ac00099a718 · doi:10.1021/ac00099a718
- Shihabi Z. K., 1995, J. Capillary Electrophor., 6, 71
- Shihabi Z. K., 1996, J. Chromatogr., A, 744, 40, 10.1016/0021-9673(96)00132-X · doi:10.1016/0021-9673(96)00132-x
- Shihabi Z. K., 1998, J. Chromatogr., A, 807, 133
- Xiong Y., 1998, Anal. Chem., 70, 11, 10.1021/ac980376j · doi:10.1021/ac980376j
- Gebauer P., 1995, Electrophoresis, 16, 50
- Krivánková L., 1997, J. Chromatogr., A, 772, 95, 10.1016/S0021-9673(97)00126-X · doi:10.1016/s0021-9673(97)00126-x
- Beckers J. L., 1993, J. Chromatogr., 641, 73, 10.1016/0021-9673(93)80153-Y · doi:10.1016/0021-9673(93)80153-y
- Tong W., 1997, J. Neuroscience Methods, 76, 201, 10.1016/S0165-0270(97)00098-8 · doi:10.1016/s0165-0270(97)00098-8
- Robert F., 1995, Anal. Chem., 67, 44, 10.1021/ac00107a013 · doi:10.1021/ac00107a013
- Durgbanshi A., 1998, J. Chromatogr., A, 798, 96, 10.1016/S0021-9673(97)00964-3 · doi:10.1016/s0021-9673(97)00964-3
- Britz-McKibbin P., 1998, Analyst (Cambridge, U.K.), 123, 3, 10.1039/a800772a · doi:10.1039/a800772a
- Britz-Mckibbin P., 1999, J. Chromatogr., A, 853, 40, 10.1016/S0021-9673(99)00689-5 · doi:10.1016/s0021-9673(99)00689-5
- Rae W. E., 1997, J. Chromatogr., A, 781, 10
- Peng X., 1997, J. Chromatogr., A, 767, 16, 10.1016/S0021-9673(96)01100-4 · doi:10.1016/s0021-9673(96)01100-4
- Landers J. P., 1992, Anal. Chem., 64, 2846, 10.1021/ac00046a032 · doi:10.1021/ac00046a032
- Vollhardt K. P. C., 1987, Organic Chemistry
- Joh T., 1990, Catecholamine Genes, 7
Cited by
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
On-line sample preconcentration in capillary electrophoresis
Simpson, S. L., Quirino, J. P., & Terabe, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.001 · Cited by 342
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Identification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
McCool, E. N., Lubeckyj, R. A., Shen, X., Chen, D., Kou, Q., Liu, X., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00693 · Cited by 117
Self-citation
Metadata
- Authors
- Britz-McKibbin, P., & Chen, D. D. Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-02-19
- Volume
- 72
- Issue
- 6
- Pages
- 1242-1252
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2034419432
- Cited by
- 310
- References
- 14
- FWCI
- 11.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective Focusing of Catecholamines and Weakly Acidic Compounds by Capillary Electrophoresis Using a Dynamic pH Junction. https://app.cochat.ai/papers/10.1021/ac990898e
- The paper
- Britz-McKibbin, P., & Chen, D. D. Y. (2000). Selective Focusing of Catecholamines and Weakly Acidic Compounds by Capillary Electrophoresis Using a Dynamic pH Junction. Analytical Chemistry. https://doi.org/10.1021/ac990898e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.