Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Convergent, Self-Encoded Bead Sensor Arrays in the Design of an Artificial Nose

Dickinson, Todd A., Michael, Karri L., Kauer, John S., Walt, David R.·1999·Analytical Chemistry

Abstract

We report a new approach to designing an artificial nose based on high-density optical arrays that directly incorporate a number of structural and operational features of the olfactory system. The arrays are comprised of thousands of microsphere (bead) sensors, each belonging to a discrete class, randomly dispersed across the face of an etched optical imaging fiber. Beads are recognized and classified after array assembly by their unique, "self-encoded" response pattern to a selected vapor pulse. The high degree of redundancy built into the array parallels that found in nature and affords new opportunities for chemical-sensor signal amplification. Since each bead is independently addressable through its own light channel, it is possible to combine responses from same-type beads randomly distributed throughout the array in a manner reminiscent of the sensory-neuron convergence observed in the mammalian olfactory system. Signal-to-noise improvements of approximately n1/2 have been achieved using this method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac981457i

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Dickinson, T. A., Michael, K. L., Kauer, J. S., & Walt, D. R.
Venue
Analytical Chemistry
Published
1999-05-04
Volume
71
Issue
11
Pages
2192-2198
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2004710970
Cited by
167
References
1
FWCI
10.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.