CoChat

Identification of Proteins in Complexes by Solid-Phase Microextraction/Multistep Elution/Capillary Electrophoresis/Tandem Mass Spectrometry

Tong, Wei, Link, Andrew, Eng, Jimmy K., Yates, John R. · 1999 · Analytical Chemistry

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

A method to directly identify proteins in complex mixtures by solid-phase microextraction (micro-SPE)/multistep elution/capillary electrophoresis (CE)/tandem mass spectrometry (MS/MS) is described. A sheathless liquid-metal junction interface is used to interface CE and electrospray ionization MS/MS. A subfemtomole detection limit is achieved for protein identification through database searching using MS/MS data. The SPE serves as a semiseparation dimension using an organic-phase step-elution gradient in combination with the second separation dimension for increased resolving power of complex peptide mixtures. This approach improves the concentration detection limit for CE and allows more proteins in complex mixtures to be identified. A 75-protein complex from yeast ribosome is analyzed using this method and 80-90% of the proteins in the complex can be identified by searching the database using the MS/MS data from a complete analysis. This multidimensional CE/MS/MS methodology provides an alternative to multidimensional liquid chromatography/MS/MS for direct identification of small amounts of protein in mixtures.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac9901182

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 31 references

Research works printed but not linked: 4

  1. Yates J. R., 1996, Use of mass spectrometry fragmentation patterns of peptides to identify amino acid sequences in databases. U.S. Patent 5,538,897
  2. Tomlinson A. J., 1995, J. Capillary Electrophor., 2, 247
  3. Tomlinson A. J., 1995, J. Capillary Electrophor., 2, 247
  4. Guzman N. A., 1999, LC-GC, 17, 16

Cited by

See all 143

Metadata

Authors
Tong, W., Link, A., Eng, J. K., & Yates, J. R.
Affiliations
University of Washington (US)
Corresponding author
Yates, John R.
Venue
Analytical Chemistry
Published
1999-05-26
Volume
71
Issue
13
Pages
2270-2278
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1994804505
Cited by
143
References
31
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 2 · 2015: 4 · 2014: 9 · 2013: 9 · 2012: 4
FWCI
7.88
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation
  • National Institutes of Health (5r01gm052095-03)
  • National Institute of General Medical Sciences (GM52095)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
protein identification, solid-phase microextraction, capillary electrophoresis, tandem mass spectrometry, electrospray ionization, peptide mixtures, yeast ribosome, database searching, multidimensional separation
MeSH terms
Hydrolysis, Proteins, Mass Spectrometry, Trypsin, Electrophoresis, Capillary

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.